FC 300 Design Guide
How to Program
" Parameters: Data Read-outs
" 16-0* General Status
16-00 Control W ord
Range:
0-0
*
0
Function:
Gives the present reference value applied on impulse
or analog basis in the unit resulting from the choice
of configuration in par. 01-00 (Hz, Nm or RPM).
16-01 Refe rence [Unit]
Range:
-999999.000 - 999999.000
*
0.000
Function:
Shows the present value of reference value
applied on impulse or analog basis in the
unit as a result of the configuration made in
par. 01 -00 (Hz, Nm or RPM).
16-02 Reference %
Range:
-200.0 - 200.0 %
*
0.0%
Function:
The value shown corresponds to the total
reference (sum of digital/analog/preset/b us/freeze
ref./catch up and slow-d own).
No Descrip-
tions
Hex Warn-
ing
Alarm Trip Trip
Lock
0 00000001
1 00000002
2 00000004
3 00000008
4 00000010
5 00000020
6 00000040
7 00000080
8 00000100
9 00000200
10 00000400
11 00000800
12 00001000
13 00002000
14 00004000
15 00008000
16 00010000
17 00020000
18 00040000
19 00080000
20 00100000
21 00200000
22 00400000
23 00800000
24 01000000
25 02000000
26 04000000
27 08000000
28 10000000
29 20000000
30 40000000
31 80000000
16-03 Status Word
Range:
0-0
*
0
Function:
Returns the status word sent from the drive via
the serial c ommunication port in hex c ode.
16-05 Main Actual Value [% ]
Option:
0-0N/A
*
N/A
Function:
Two-byte word sent with the Status word to the
Bus Master rep orting the main actual value.
Please refer to the VLT
®
AutomationDrive FC
300 Profibus Operating Instructions MG.33.CX.YY
for detailed description.
" 16-1* Motor Status
16-10 Power [kW]
Range:
0.0 - 1000.0 kW
*
0.0kW
Function:
The value shown is calculated on t
he basis of
the actual motor voltage and motor current.
The value is filtered. Thus, approx. 1.3 s m ay
pass from when an input change
s value until
the data readout values change.
16-11 Power [hp]
Range:
0.00 - 1000.00 hp
*
0.00hp
Function:
The value shown is calculated on the basis of the
actual motor voltage an
d motor current. The
value is indicated in the unit of horsepower. The
value is filte red . Thus, approx. 1.3 seconds may
*
default setting ()display text []value for use in communication via serial communication port
214
MG.33.B
3.22 - VLT is a registered Danfoss trademark

Table of Contents

Other manuals for Danfoss VLT AutomationDrive FC 302

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT AutomationDrive FC 302 and is the answer not in the manual?

Danfoss VLT AutomationDrive FC 302 Specifications

General IconGeneral
BrandDanfoss
ModelVLT AutomationDrive FC 302
CategoryDC Drives
LanguageEnglish

Related product manuals