FC 300 Design Guide
How to Program
" Additional Text
With this feature, it is possible to read additional
text if bit 10, Additional te xt available,is
true in Basic characteristics.
To read out additional text, the parameter command
(PKE) must b e set to F hex, see Databytes.
The index field is used for pointing out which
element to read. Valid indexes are in the range
of 1 through 254. The index must be calculated
according t o the following equation:
Index = Parameter value + 1 (see table be low).
Value Index Text
01English
12Deutsch
23Français
34Dansk
45Espanol
56Italiano
Example:
In this exam ple, the Maste r reads additional text in par. 0-01 , Language. The telegram is set up to read
data value [0] (English). You must send the following telegram to the adjustable frequency drive:
STX LGE ADR PKE IND PWE
HIGH
PWE
LOW
PCD1 PCD2 BCC
02 0E 01 F0 01 00 01 00 00 00 00 XX XX XX XX XX
STX = 02 Start byte
LGE = 0E Length of the remaining telegram
ADR = Send the VLT adjustable frequency drive on A ddress 1, Danfoss format
PKE = F001; F in the PKE field indicates a Read text and 01 indicates par. 0-01, Language .
IND = 0001; 1 indicates that text to parameter value [0] is required
The response from the adjustable frequency drive is:
STX LGE ADR PKE IND PVA PCD1 PCD2 BCC
02 11 01 F0 01 00 01 454E 474C 4953 48 XX XX XX XX XX
PKE= F001;FistheresponseforText transfer and 01 indicates par. 0-01, Language.
IND = 0001; 1 indicates that index [1] is sent
PVA = 45 4E 47 4C 49 53 48
ENGLISH
Theparametervaluechannelisnowsetuptoavisiblestring,whichreturnsanASCII
character for each letter in the index name.
*
default setting ()display text []value for use in communication via serial c ommunication port
261
MG.33.B
3.22 - VLT is a registered Danfoss trademark

Table of Contents

Other manuals for Danfoss VLT AutomationDrive FC 302

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT AutomationDrive FC 302 and is the answer not in the manual?

Danfoss VLT AutomationDrive FC 302 Specifications

General IconGeneral
BrandDanfoss
ModelVLT AutomationDrive FC 302
CategoryDC Drives
LanguageEnglish

Related product manuals