FC 300 Design Guide
Introduction to FC 300
Digital output
Programmable digital/pulse outputs ................................................................................................2
Terminal number ................................................................................................................. 27, 29
1)
Voltage level at digital/frequency output . ................................................................................ 0 - 24 V
Max. output current (sink or source) ........................................................................................ 40 mA
Max. load at digital/frequency output .......................................................................................... 1 k
Max. load at digital/frequency output ......................................................................................... 10 nF
Minimum output frequency at frequency output ........................................................................... 0 Hz
Maximum output frequency at frequency output ....................................................................... 32 kHz
Accuracy on frequency output ................................................................. Max. error: 0.1% of full scale
Resolution on frequency output ................................................................................................ 12 bit
1) Terminal 27 and 29 can also be programmed as intput.
The digital output is galvanically isolated from the supply voltage (PELV ) and othe r high-voltage terminals.
Control card, 24 V DC output:
Terminal number ................................................................................................................... 12, 13
Max. load ...................................................................................... FC 301: 130 mA / FC 302: 200 mA
The 24 V DC supply is galvonically isolated from the supply voltage (PELV), but has the same
potential as the analog and digital inputs and outputs.
Relay outputs:
Programmable relay outputs ............................................................................. FC 301: 1 / FC 302: 2
Relay 01 Terminal number .............................................................................. 1-3 (break), 1-2 (make)
Max. terminal load (AC) on 1-3 (NC), 1-2 (NO) ............................................................... 240 V AC, 2 A
Max. terminal load (DC) on 1-2 (NO), 1-3 (NC) ................................................................. 60 V DC, 1A
Relay 02 (FC 302 only) Terminal number .......................................................... 4-6 (break), 4 -5 (make)
Max. terminal load (AC) on 4-5 (NO) ............................................................................. 400 V AC, 2 A
Max. terminal load (DC) on 4-5 (NC) .............................................................................. 80 V DC, 2 A
Max. terminal load (DC) on 4-6 (NC) .............................................................................. 50 V DC, 2 A
Min. terminal load on 1-3 (NC), 1-2 (NO), 4-6 (NC), 4-5 (NO) ................. 24 V DC 10 mA, 24 V AC 100 mA
Environment according to EN 60664-1 ................................... overvoltage category III/pollution degree 2
The relay contacts are galvanically isolated from the rest of the circuit by reinforced isolation (SELV).
Control card, 10 V DC output:
Terminal number ......................................................................................................................... 50
Output voltage ............................................................................................................ 10.5 V ±0.5 V
Max. load ............................................................................................................................. 15 mA
The 10 V DC supply is galvonically isolated from the supp ly voltage (PELV ) and other high-voltage terminals.
Control c haracteristics:
Resolution of output frequency at 0 - 1000 Hz ........................................................................ 0.013 Hz
Repeat accuracy of Precise start/stop (terminals 18, 19) ............ FC 301: ±1ms/FC302: ±0.1msec
System response time (terminals 18, 1 9, 27, 29, 32, 33) ................... FC 301: 20 ms / FC 302: 2ms
Speed control range (open loop) ............................................................... 1:100 of synchronous speed
Speed control range (closed loop) ............................................................ 1:1000 of synchronous speed
Speed accuracy (open loop) ......................................................... 30 - 4000 rpm: Max. e rror of ±8 rpm
Speed accuracy (closed loop) .................................................... 0 - 6000 rpm: Max. error of ±0.15 rpm
All control characteristics are based on a 4-pol e asynchronous motor
59
MG.33.B3.22 - VLT is a registered Danfoss trademark

Table of Contents

Other manuals for Danfoss VLT AutomationDrive FC 302

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT AutomationDrive FC 302 and is the answer not in the manual?

Danfoss VLT AutomationDrive FC 302 Specifications

General IconGeneral
BrandDanfoss
ModelVLT AutomationDrive FC 302
CategoryDC Drives
LanguageEnglish

Related product manuals