FC 300 Design Guide
How to Program
" 1-** Load/Motor
Par.
No. #
Parameter description Default value 4-set-up Change
during
operation
Conver-
sion index
Type
1-0* General settings
1-00 Configuration mode [0] Speed open loop All set-ups FALSE - Uint8
1-01 Motor control principle [1] VVCplus All set-ups FALSE - Uint8
1-2* Motor data
1-20 Motor power [HP] Drive dependent All set-ups FALSE 1 Uint32
1-22 Motor voltage Drive dependent All set-ups FALSE 0 Uint16
1-23 Motor frequency Drive dependent All set-ups FALSE 0 Uint16
1-24 Motor current Drive dependent All set-ups FALSE -2 Uint16
1-25 Motor nominal speed Drive dependent All set-ups FALSE 67 Uint16
1-29 Automatic motor adaptation(AMA) [0] Off All set-ups FALSE - Uint8
1-3* Advanced motor data
1-30 Stator resistance (Rs) Motor dependent All set-ups FALSE -4 Uint32
1-31 Rotor resistance (Rr) Motor dependent All set-ups FALSE -4 Uint32
1-33 Stator leakage reactance (X1) Motor d ependent All set-ups FALSE -4 Uint32
1-34 Rotor leakage reactance (X2) Motor dependent All set-ups FALSE -4 Uint32
1-35 Main reactance (Xh) Motor dependent All set-ups FALSE -4 Uint32
1-36 Iron loss resistance (Rfe) Motor dependent All set-ups FALSE -3 Uint32
1-39 Motor poles Motor dependent All set-ups FALSE 0 Uint8
1-5* Load indep. setting
1-50 Motor magnetizing at zero speed 100 % All set-ups TRUE 0 Uint16
1-51 Min speed normal magnetizing [RPM] 1 RP M All set-ups TRUE 67 Uint8
1-6* Load depen. setting
1-60 Low speed load compensation 100 % All set-ups TRUE 0 Int16
1-61 High speed load compensation 100 % All set-ups TRUE 0 Int16
1-62 Slip compensation 100 % All set-ups TRUE 0 Int16
1-63 Slip compensation time constant 0.10 s All set-ups TRUE -2 Uint16
1-64 Resonance dampening 100 % All set-ups TRUE 0 Uint16
1-65 Resonance dampening time constant 5 ms All set-ups TRUE -3 Uint8
1-66 Min. current at low speed 100 % All set-ups TRUE 0 Uint8
1-67 Load type [0] Passive load All set-ups TRUE - Uint8
1-68 Minimum inertia Drive dependent All set-ups FALSE -4 U int32
1-69 Maximum inertia Drive dependent All set-ups FALSE -4 Uint32
1-7* Start adjustments
1-71 Start delay 0.0 s All set-ups TRUE -1 Uint8
1-72 Start function [2] Coast/delay time All set-ups TRUE - Uint8
1-74 Sta rt speed [RPM] 0 RPM All set-ups T RUE 67 Uint16
1-76 Start c urrent 0.00 A A ll set-ups TRUE -2 Uint16
1-8* Stop adjustments
1-80 Function at stop [0] Coast All set-ups TRUE - Uint8
1-81 Min s peed for function at stop [RPM] 0 RPM All set-ups TRUE 67 Uint16
1-9* Motor temperature
1-90 Motor thermal protection [0] No protection All set-ups TRUE - Uint8
1-91 Motor external fan [0] No All set-ups TRUE - Uint16
1-93 Thermistor source [0] None All set-ups FALSE - Uint8
*
default setting ()display text []value for use in communication via serial c ommunication port
222
MG.33.B
3.22 - VLT is a registered Danfoss trademark

Table of Contents

Other manuals for Danfoss VLT AutomationDrive FC 302

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT AutomationDrive FC 302 and is the answer not in the manual?

Danfoss VLT AutomationDrive FC 302 Specifications

General IconGeneral
BrandDanfoss
ModelVLT AutomationDrive FC 302
CategoryDC Drives
LanguageEnglish

Related product manuals