Parameters ASDA-B2-F
7-54 September, 2015
7
Z: P parameters will be overwritten by DMCNET parameters.
Z = 0: When re-servo on the servo drive or reset the communiation, P parameters that mentioned
in the following table will load in the value of DMCNET parameters.
Z = 1: When re-servo on the servo drive or reset the communiation, P parameters that mentioned
in the following table will remain its original setting. The value of DMCNET parameters will
not be loaded in.
DMCNET Parameter:
P3-13 ~ P3-16
Reserved
DMCNET Parameter P Parameter
Parameter Default Parameter Default
P1-32
DMCNET
0 P1-32
P1-32.Y = 0,
Dynamic break enable
P1-32.Y = 1,
Dynamic break disable
P2-35
DMCNET
3840000 P2-35 3840000
P1-47
DMCNET
100
(0.1 rpm)
P1-47 10 (rpm)
P1-49
DMCNET
0 P1-49 0
P1-38
DMCNET
100 P1-38 100
P1-44
DMCNET
1:1 P1-44/P1-45 128:10
P1-45
DMCNET