Installation and Operation Manual for RPI M6A M8A M10A inverters V1.0 2016-02-03
8 Settings
8.7 Insulation mode and insulation resistance
Description
With this function you can set up the mode of insulation and the insulation resistance.
Accessing the menu
Main menu > Install Settings > Insulation
E-Today: 0kWh
Power: 0W
Status: On Grid
10.Sep 2014 15:32
1. When the default information is displayed, press any button to open the main menu. Oth-
erwise, repeatedly press the button
ESC
until the main menu is displayed.
Inverter Info.
General Settings
2. Use the buttons and to select Install Settings.
To conrm your selection, press the button
ENT
.
energy production
Adj. would effect
Warning:
3. The menu is protected by password 5555. Use the buttons and to set each digit.
To conrm a digit, press the button
ENT
.
4. Use the buttons and to select Insulation.
To conrm your selection, press the button
ENT
.
Resistance: 1200 kΩ
Mode: ON
5. Use the buttons and to select Mode. The currently set mode of insulation is dis-
played behind the menu entry.
To conrm your selection, press the button
ENT
.
Plus grounded
Minus grounded
6. Use the buttons and to select a type of insulation.
To conrm your selection, press the button
ENT
.
Resistance: 1100 kΩ
Mode: ON
7. Use the buttons and to select Resistance. The currently set value for the insu-
lation resistance is displayed behind the menu entry.
To conrm your selection, press the button
ENT
.
Do not change this setting without prior