85
Installation and Operation Manual for RPI M6A M8A M10A inverters V1.0 2016-02-03
8 Settings
Set Point: 100%
Mode: ON
6. To change the mode, use the buttons and and press the button
ENT
.
To switch the function on, select ON and press the button
ENT
.
To switch the function off, select OFF and press the button
ENT
. When you switch the
function off, you can ignore the following steps.
Set Point: 100%
Mode: ON
7. To set the value for the power limitation, use the buttons and to select Set
Point and press the button
ENT
.
8. Use the buttons and to change the parameter value.
To conrm your setting, press the button
ENT
.
To cancel the action, press the button
ESC
.
Congurable Parameters
Parameter Description Value range
Mode
Switches the function on and off.
ON | OFF
Default value: OFF
Set Point
The value for the power limitation.
0 ... 100%
Default value: 100%
Do not change this setting without prior
consultation with Delta Solar Support.