3590EKR, 3590EXP, 3590EXT, CPWE, CPWET series indicator E-AF09_02_16.03_EN_U
The operation can be made either with a loaded or unloaded platform.
NOTE
- In the printout, the manual tare is identified with “PT” (Preset Tare).
7.2 CALCULATED MANUAL TARE
With the "CALCULATOR" function one can add or subtract from the current tare the result of an operation between two
values entered with the keyboard.
For the functioning specifics see the 15.3 CALCULATOR section.
7.3 TARE CANCELLATION
To cancel the stored tare:
- Deselect the active vehicle.
- With an unloaded platform, press the TARE key.
- With loaded platform press in sequence the numeric 0 key and TARE.
- Press the C key.
NOTE: the selection of vehicle linked to a tare equal to 0 has no effect on the present tare.
7.4 LOCKED/UNLOCKED TARE
Normally, when a tare value has been entered (automatically, manually or from storage), if one unloads the scale plate, the
tare value remains active (LOCKED TARE). One can also choose that the tare value is cancelled automatically each time
that the scale is unloaded (LOCKED TARE):
In case of SEMIAUTOMATIC TARE, the net weight before the scale unloading may also be 0.
In case of MANUAL TARE, the net weight before the scale unloading must be of at least 2 stable divisions.
If the F5 key is pressed at length, it is possible to quickly lock/unlock the tare:
DISPLAY MEANING
LoCK LOCKED TARE
unLoCK UNLOCKED TARE
The setting of the tare may be made also in the "TARE LOCK/UNLOCK" SEtuP >> tare t parameter of the TECHNICAL
SETUP, TECH.MAN.REF.
7.5 LIMITATION OF THE TARE FUNCTIONS
For specific requirements, it is possible to limit the tare functions with approved instrument; by setting “YES” in the SEtuP
>> d.SALE step of the SET-UP environment (TECH.MAN.REF.):
- the SEMIAUTOMATIC TARE can not be modified with a manual or calculated tare.
- the manual or calculated tare must be entered or modified only with an UNLOADED scale.
With approved instrument, the SEtuP >> d.SALE step is read-only.
7.6 TARE EXECUTION MODE OR DISABLING OF THE TARE
It’s possible to select the tare execution mode, through the setting of the F.ModE >> totAL >> tArE t step
(TECH.MAN.REF.):
- By setting "diSAbL" one disables all the tare operations;
- By setting "Lock" or “Unlock”, all the tare operations described in section 7.4 are enabled.
7.7 ENTERING OF A PRESET TARE IN A VEHICLE IN THE DATABASE.
It is possible to enter a known tare value in each vehicle in the database; this value will be enabled with each selection of the
vehicle.
See section 11.3 for further details.

Table of Contents

Other manuals for Dini Argeo 3590ET

Question and Answer IconNeed help?

Do you have a question about the Dini Argeo 3590ET and is the answer not in the manual?

Dini Argeo 3590ET Specifications

General IconGeneral
BrandDini Argeo
Model3590ET
CategoryAccessories
LanguageEnglish

Summary

1. Introduction to the Weight Indicator

2. Main Technical Specifications Overview

Details power supply, operating temperature, converter, speed, signal range, and display characteristics.

3. Installation Procedures

3.1 Power Supply and Connections

Details power options (12Vdc, 24Vdc, battery) and connection safety regulations.

4. Front Panel Key Functions

4.1 Key Functionality Overview

Describes the specific actions of keys like C/DEL, TARE/ZERO, Fn/ENTER, and 2nd F.

5. Display and Status Indicators

5.2 Status Indicator Meanings

Details the meaning of LED indicators and symbols on the LCD display.

5.5 Instrument Messages and Errors

6. Scale Zeroing Procedure

7. Tare Function Management

7.1 Manual Preset Tare Entry

Details methods for entering a tare value to subtract from accumulated weight.

11. Database Management

11.1 Customer Database Operations

Covers entry, modification, deletion, printing, selection, and research of customer data.

11.2 Material Database Operations

Covers entry, modification, deletion, printing, selection, and research of material data.

12. Database Access Password Protection

13. Weighing Procedures

13.1 System Overview

Provides a general overview of the weighing system and its management capabilities.

13.2 Simple Axle Weighing Modes

Explains manual, automatic static, and automatic dynamic axle weighing without I/O.

13.3 Input-Output Axle Weighing Modes

Describes manual, auto static, and auto dynamic axle weighing with input/output.

13.4 Automatic Axle Weighing Cycle Functions

Covers functions for managing automatic axle weighing cycles like cancelling and error handling.

14. Printout Functions

Reports with Preset Tare

Details reports for I/O weighing with preset tare, including weight difference.

14.1 Print Format Linking

Linking Formats to Print Functions

How to link print formats to specific print functions.

Quick Format Linking Methods

Provides shortcuts for linking formats to print functions.

14.4 Default Printing Formats

15. Additional Instrument Functions

15.6 Set-Point Function Configuration

Setpoints Based on Gross Weight

Configures setpoints for gross weight activation/deactivation of outputs.

Setpoints Based on Net Weight

Configures setpoints for net weight activation/deactivation of outputs.

Control Light Functionality

Uses outputs as control lights to guide driver for axle positioning.

Setpoint on Axle Total

Enables relay on sum of acquired axles, based on enabling setpoint.

Exclusive Functioning Mode for Outputs

Configures exclusive use of outputs, creating activation ranges.