3590EKR, 3590EXP, 3590EXT, CPWE, CPWET series indicator E-AF09_02_16.03_EN_U
8. MULTIRANGE AND MULTIDIVISION FUNCTION
The multi range functioning allows to subdivide the scale capacity in two or three ranges, each which is up to 3000
divisions, improving in this way the first range division in the dual range and the first two ranges in the triple range.
For example, it is possible to approve the weighing system with:
- A single range: 6 kg capacity and 2 g division (3000 div.).
- Dual range: 6 / 3 kg capacity and 2/1 g division (3000 + 3000 div.).
- Triple range: 15 / 6 / 3 kg capacity and 5 / 2 / 1 g division (3000 + 3000 + 3000 div.).
NOTE: For the approval of the weighing system in dual and triple range the cell must have better technical features in
comparison to the cell used for the approval in a single range.
This functioning is indicated by the turning on of the LEDs which identify the range in which one is working: W1 first range,
W2 second range, W3 third range (if configured); by passing to the W2 range, the second range division is enabled; by
passing to the W3 range, the third range division is enabled, at this point the W1 first scale division is restored only by
passing the gross zero of the scale.
The multidivisional functioning is similar to multirange, but with the difference that a range division is enabled as soon as
one enters in its range interval (in other words without passing by the scale zero).
NOTE: The selection of the range number with multirange and multidivisional functioning is made during the indicator
calibration (TECH.MAN.REF.).
9. DISPLAY OF METRIC DATA (inFO)
The indicator is fitted with a function named “INFO”, thanks to which it is possible to view the configuration metric data:
- First range capacity, first range minimum weigh, first range division.
- Second range capacity, second range minimum weigh, second range division.
- Third range capacity, third range minimum weigh, third range division.
NOTES:
- The minimum weigh corresponds to 20 net weight divisions.
- The data of the second and third range appear only if actually configured.
To display the metric data:
- Press in sequence the 2ndF and C key
- “METROLOGIC INFORMATION” is displayed
- The display will show the number of the scale, the type of displayed data and its value.
- Press the F6 key to quickly scroll the following data
- Press the F7 key to quickly scroll the previous data backwards.
- Press the C key to quickly return to weighing.
10. FILLING IN THE INPUT TEXT
The indicator offers the possibility of using 15 CONFIGURABLE INPUT TEXTS (for example LOT, OPERATOR, SHIFT, etc.),
each made up of 16 heading characters and 32 content characters.
When entered in the TECHNICAL SET-UP (see F.ModE >> tXt “Input text configuration” parameter, TECH.MAN.REF.),
these may be printed later on, if programmed in the printouts; or these may be used as a reminder.
To manually fill in the input texts it is possible to proceed in two ways:
1) If one knows the memory storage position (from 0 to 14) of the text to be modified, type the number, followed by
the F4 key: now enter the text and confirm with ENTER (the indicator returns to the weighing phase).
2) By pressing for an instant the F4 key, one accesses the complete list of the texts, for example:
a. The LCD display shows “in. XX” in the first line, in which XX is the index of the free text (from 0 to 14) and
THE HEADING on the second line (or “Empty…” if empty).
b. Use the arrow keys to select the text to be filled in and press ENTER: now one can enter the
alphanumeric text in the second line of the LCD display, (see chapter 4.1.2 ENTERING ALPHANUMERIC
TEXT).