NetworX Version 3 Installation Manual
126
7 =
On: if configuration group is force armable
8 =
On: if configuration group is entry guard
Segment 3
1 =
On: enables Fast Loop Response. (50mS) - Off= 500mS
2 =
On: enables Double End Of Line Tamper zone. (Mainly used for tamper on
wireless zones)
3 =
On: enables Trouble Reporting zone. (Day zone and Fire zones)
4 =
On: if configuration group is a Cross Zone
5 =
On: enables Dialer Delay zone. (See location 40)
6 =
On: if configuration group will use swinger shutdown. (See location 38)
7 =
On: enables Restore reporting
8 =
On: enables Listen-In. (See location 40)
Segment 4
1 = On: enables zone activity monitor
2 = On: enables end of line resistor defeat on non-fire/non-keyswitch zones
3 = On : enables zone to act as request to exit input / disables for alarm
activation
4 = On: enables zone to act as access entry point (Door Shunt) (*)
5 = Reserved
6 = Reserved
7 = Reserved
8 = Reserved
Segment 5
1-8 Reserved
(*) Note:
Refer to NX-17xx door control installer manual. Do not enable this segment unless
configured with Door Control.
LOCATION 112 - CONFIGURATION GROUP 2 ALARM EVENT CODE (1 segment, numerical data)
Location 112 contains the event code that is sent for a Contact ID or SIA report. The desired event
code should be chosen from the Table 38 or Table 39 in Appendix 1. The zone ID will be the zone
that is in alarm.
This location is not used for slow speed formats (like 4+2 and 3+1). This location may also contain
the alarm report code for the Robofon format (value 00-99).
LOCATION 113 - CONFIGURATION GROUP 2 CHARACTERISTIC SELECT (5 segments, feature
selection data)
Use the “Configuration Group Characteristic Selections” described in Location 111.
LOCATION 114 - CONFIGURATION GROUP 3 ALARM EVENT CODE (1 segment, numerical data)
Location 114 contains the event code that is sent for a Contact ID or SIA report. The desired event
code should be chosen from the Table 38 or Table 39 in Appendix 1. The zone ID will be the zone
that is in alarm.
This location is not used for slow speed formats (like 4+2 and 3+1). This location may also contain
the alarm report code for the Robofon format (value 00-99).