menu. Select Installer Menu>Maintenance Mode>Advanced Menu>Enabled and press OK. Then
select Installer Menu>Control Panel>Arm Schedules.
Note: If reports are sent, the user code will be 97 in logs and reports.
Note: If an alarm happens during the period of time when the system is automatically armed, the system will not
automatically disarm. In order to disarm the system after an alarm the user code is required.
Setting up schedules
You can set up a schedule to control the opening and autoarming events for each partition. The
following example sets a schedule for partition 1 so that it is automatically closed at 18.00 on a
Monday if there is no activity in the building. If there is activity at closing time, the control panel will
try to arm after every 45 minutes of inactivity until the next opening time, or until the system is
armed manually.
1. Ensure the advanced menu is enabled.
2. Navigate with the ½¾ keys to Control Panel>Arm Schedules and press OK.
3. Scroll to Auto Arm>Partition 1>Sunday>Yes and press OK.
4. The keypad beeps once to accept the change and returns to Sunday.
5. Scroll to 45 Minute Retry>Enabled and press OK.
6. The keypad beeps once to accept the change and returns to 45 Minute Retry.
7. Navigate with the ½¾ keys to Schedule Times>Closing/Autoarm>Hour and press OK.
8. Enter 18 and press OK.
9. The keypad beeps once to confirm the change and returns to Hour.
10. Scroll to Minute and press OK.
11. Enter 0 and press OK.
12. The keypad beeps once to confirm the change and returns to Minute.
Glossary
Location Term Definition
2 Control Panel This groups all options relating to the central processing
unit of the alarm system. The control panel monitors the
detection devices and activates any number of signalling
devices.
2.1 Inputs A menu entry that groups options relating to all zones.
2.1.1 Zones A menu entry that groups zone options.
2.1.1.1.1 Zone Type A menu option that specifies the zone type of a particular
zone.
2.1.1.1.2 Zone Name A menu option that allows the installer to define names for
each installed zone. For example, Zone 1 can be named
Living Room PIR.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE NetworX V3 and is the answer not in the manual?

GE NetworX V3 Specifications

General IconGeneral
BrandGE
ModelNetworX V3
CategorySecurity System
LanguageEnglish

Related product manuals