NetworX Version 3 Installation Manual
182
Disabling wireless sensors
You can program a receiver to disable a wireless sensor. This does not remove the sensor
identification from the module’s memory. The wireless sensor can be reactivated later or a new
sensor can be learned into the zone. The following example removes sensor 10 learned in on receiver
32.
1. Navigate with the ½¾ keys to RF Receivers>RF Receiver 32 and press OK.
2. Scroll to Inputs>Sensor 10>Enabled>No and press OK.
3. The keypad beeps once to accept the change and returns to Enabled.
Glossary
Term Definition
1 Pulse On A menu entry that groups options enabling/disabling a single siren pulse at
arming or at the exit delay expiration. This options work for the following
output events only: Any siren, Burglary siren, Burglary alarm, 24 hour alarm.
Antipassivation A menu entry that enables/disables the siren's battery antipassivation feature.
When enabled, a small current flows through IO module output 2 every 30
seconds in order to improve the siren's battery life.
Attributes A menu entry that groups additional configuration options for IO modules.
Code Stops Timer A menu option that specifies the way entering code by the user affects the way
the output is timed. If set to Yes, the output should be reset if a code is entered
while it is being timed. When set to No, the output stays timed (not reset) after
a code is entered.
Note: Do not set up this option for system status events (such as "Ready to
Arm", "Not Ready to Arm", "Armed", "Disarmed") because once the output is
triggered it will not reset to reflect current status unless the user code is
entered.
Del. RF Device A menu entry that groups entries related to deleting RF devices from the
system.
Del. RF Keypad A menu entry that allows to delete the selected RF keypad.
Del. RF Sensor A menu entry that allows to delete the selected RF sensor (zone).
Del. RF Sir/IO A menu entry that allows to delete the selected RF siren or IO module.
Door/Window A RF Receiver menu option that configures door/window settings on an RF
receiver. It includes the use of internal reed and additional external contact of
the door/windows transmitters.
Enabled A menu entry that enables/disables the selected sensor.
Event Selects the event that will trigger the output. See Table 22 for the specific
events that can be selected.