NetworX Version 3 Installation Manual
173
The built-in wireless receiver of the NetworX V3 is compatible with wireless sensors and keyfobs of
the type 868MHz Generation 2 only. Existing receivers (868MHz FM and 433MHz AM) can also be
connected to the NetworX V3 databus. The NetworX V3 built-in receiver is enrolled as module 32.
Defaulting the wireless modules
You must enrol and default each RF receiver before you begin programming the system.
1. Navigate with the ½¾ keys to RF Receivers and press OK.
2. Select the relevant module bus ID and press OK. In this case select RF Receiver 32 and
press OK.
3. Select Reset Settings and press OK.
4. A confirmation message is displayed. Press OK to accept the default settings.
5. The keypad sounder beeps once to confirm the reset.
Programming the wireless detectors
1. Navigate with the ½¾ keys to RF Receivers and press OK.
Note: It is recommended to not learn any devices from keypad which belongs to a partition different then Partition 1.
2. Select the relevant module bus ID and press OK. In this case select RF Receiver 32 and
press OK.
3. Scroll to Start Zone and press OK.
4. Enter the starting zone of the receiver. In case of the RF Receiver 32 (the NetworX V3
built-in 868MHz Gen2 receiver), this option is not visible. In the NetworX V3 system,
you can set this value for additional RF receivers only. For the RF receiver 32, the
starting zone is always zone 1.
5. Scroll to Learn RF Device and press OK.
6. To learn-in more than one device, scroll to Sequential Programming, select Yes and press
OK.
7. Scroll to Learn RF Zone and press OK.
8. Enter the zone number to start with. In this case, enter 9 to program the detectors in zones
9 and 10 and press OK.
9. Tamper the different detectors in sequence. To do this, you activate the sensor’s tamper
switch.
Table 21 Learning RF transmitters explains how to activate each type of sensor.
Table 21. Learning RF transmitters
Transmitter Action
Door/Window Activate the tamper switch by removing the cover.
PIR Activate the tamper switch by removing the cover.
DUAL Activate the tamper switch by removing the back plate from the DUAL.