NetworX Version 3 Installation Manual
272
Status LED Yes KP
This Keypad>Keypad Features>Advanced
Options>Status LED
Status LED Always On Yes KP
This Keypad>Keypad Features>Advanced
Options>Status LED Always On
Tamper when removed from wall Yes KP
This Keypad>Keypad Features>Pry Off
Switch>Always Tamper
LED Extinguish Yes KP
This Keypad>Keypad Features>Advanced
Options>LED Extinguish
Jam Detection Yes RM
RF Receivers>RF Receiver 32>Receiver Features>Jam
Detection
Fire Supervision No RM
RF Receivers>RF Receiver 32>Inputs>Sensor n>Fire
Supervision (for each sensor)
Normal Window 1 hour RM
RF Receivers>RF Receiver 32>Receiver
Features>Supervision>Normal Window
Short Window
20
minutes RM
RF Receivers>RF Receiver 32>Receiver
Features>Supervision>Short Window
Supervised Yes RM
RF Receivers>RF Receiver 32>Inputs>Sensor
n>Supervised (for each sensor)
Wake On Entry Timer Yes RM
RF Receivers>RF Receiver 32>Receiver
Features>Wake Up Options>RF Keypad n>Wake On
Entry Timer (for each keypad)
Wake On Exit Timer Yes RM
RF Receivers>RF Receiver 32>Receiver
Features>Wake Up Options>RF Keypad n>Wake On
Exit Timer (for each keypad)
Wake On Pulsing Buzzer Yes RM
RF Receivers>RF Receiver 32>Receiver
Features>Wake Up Options>RF Keypad n>Wake On
Pulsing Buzzer (for each keypad)
Alarm signal timer for sirens
Maximum
of 15
minutes;
if more
than 15
minutes
then 3
minutes
are set. RM
RF Receivers>RF Receiver 32>Outputs> I/O x Output
y
>Time Unit>Minutes (for each siren)
RF Receivers>RF Receiver 32>Outputs>I/O x Output y
>Time (for each siren)
All sirens must be learned-in before switching to the
EN mode.
Users
Access levels
According to the EN 50131 standard, there are 4 access levels which determine who can operate the
system.
Access Level 1 - General public (limited to viewing status).
Access Level 2 - Users and the Master user.
Access Level 3 - Installer, but only with Access Level 2 permission.
Access Level 4 - Manufacturer, but only with with Access Level 2 and Access Level
3 permission. Access Level 4 is optional.

Table of Contents