EasyManuals Logo
Home>GE>Security System>NetworX V3

GE NetworX V3 User Manual

GE NetworX V3
286 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #271 background imageLoading...
Page #271 background image
NetworX Version 3 Installation Manual
271
RF Low Battery Yes CP
Control Panel>Communications>Reporting>System
Reports>Tamper/Fault>RF Low Battery
RF Sensor Lost Yes CP
Control Panel>Communications>Reporting>System
Reports>Tamper/Fault>RF Sensor Lost
Failure To Communicate report
enabled
Yes CP
Control Panel> Communications>Central
Station>Phone Numbers>Phone Number
n>Events>Communications>Fail to Communicate
Autotest report enabled Yes CP
Control Panel>Communications>Reporting>System
Reports>Communications>Autotest
Summer/wintertime automatic
switch Enabled CP
Control Panel>System Settings>Feature
Select>Clock>Summer/Winter Time
Installer code can arm/disarm Yes CP
Control Panel> Codes>Installer
Code>Authority>Arm/Disarm
Reports Open/Close for the
installer code Yes CP
Control Panel> Codes>Installer Code>Authority>
Reports Open/Close
LED Extinguish No CP
Control Panel>Partition Settings>Partition n>Feature
Select>Keypads>LED Extinguish
AC power/low battery sounder
alert No CP
Control Panel>Partition Settings>>Partition n>Feature
Select>Miscellaneous>Mains/Batt Sounder Alert
Silent exit No CP
Control Panel>System Settings>Features
Select>Miscellaneous>Silent Exit Always
FTC Report Attempts 6 GSM
NX-7002 Module>Reporting>Report Attempts>FTC
Report Attempts
Line Fault Indication Yes GSM NX-7002 Module>Reporting>Line Fault Indication
Line Fault Reporting Yes GSM NX-7002 Module>Reporting>Line Fault Reporting
Report Timeout 60 GSM
NX-7002 Module>Reporting>Report Attempts>Report
Timeout
Receiver Polling Enabled GSM
NX-7002 Module>Reporting> TCP/IP Reporting>
Receiver Polling
Polling Time 1 minute GSM
NX-7002 Module>Reporting> TCP/IP Reporting>
Polling Time
Max Reports in 24 Hours 0 GSM
NX-7002 Module>Reporting> Report Attempts> Max
Reports in 24h
HomeText Control Disabled GSM
NX-7002 Module>Options> HomeText >System
Control>HomeText Control
Battery Change Allowed No KP
This Keypad>Keypad Features> Battery Change
Allowed
Case Tamper Yes KP This Keypad>Keypad Features>Case Tamper
F1 Functional Key
Alarm
Memory KP This Keypad>Function Keys>F1 Function
Hide PINs Yes KP
This Keypad>Keypad Features>Advanced
Options>Hide PINs
Beep on RF loss No KP
This Keypad>Keypad Features>Advanced
Options>Beep on RF loss
KP Shutdown allows Disarm Yes KP
This Keypad>Keypad Features>Advanced
Options>KP Shutdown allows Disarm (recommended)
KP Shutdown shows Clock Yes KP
This Keypad>Keypad Features>Advanced Options>
KP Shutdown shows Clock
Latch Faults Until Viewed No KP
This Keypad>Keypad Features>Advanced
Options>Latch Faults Until Viewed
Silent Keypad No KP This Keypad>Keypad Features>Silent Keypad