NetworX Version 3 Installation Manual
271
RF Low Battery Yes CP
Control Panel>Communications>Reporting>System
Reports>Tamper/Fault>RF Low Battery
RF Sensor Lost Yes CP
Control Panel>Communications>Reporting>System
Reports>Tamper/Fault>RF Sensor Lost
Failure To Communicate report
enabled
Yes CP
Control Panel> Communications>Central
Station>Phone Numbers>Phone Number
n>Events>Communications>Fail to Communicate
Autotest report enabled Yes CP
Control Panel>Communications>Reporting>System
Reports>Communications>Autotest
Summer/wintertime automatic
switch Enabled CP
Control Panel>System Settings>Feature
Select>Clock>Summer/Winter Time
Installer code can arm/disarm Yes CP
Control Panel> Codes>Installer
Code>Authority>Arm/Disarm
Reports Open/Close for the
installer code Yes CP
Control Panel> Codes>Installer Code>Authority>
Reports Open/Close
LED Extinguish No CP
Control Panel>Partition Settings>Partition n>Feature
Select>Keypads>LED Extinguish
AC power/low battery sounder
alert No CP
Control Panel>Partition Settings>>Partition n>Feature
Select>Miscellaneous>Mains/Batt Sounder Alert
Silent exit No CP
Control Panel>System Settings>Features
Select>Miscellaneous>Silent Exit Always
FTC Report Attempts 6 GSM
NX-7002 Module>Reporting>Report Attempts>FTC
Report Attempts
Line Fault Indication Yes GSM NX-7002 Module>Reporting>Line Fault Indication
Line Fault Reporting Yes GSM NX-7002 Module>Reporting>Line Fault Reporting
Report Timeout 60 GSM
NX-7002 Module>Reporting>Report Attempts>Report
Timeout
Receiver Polling Enabled GSM
NX-7002 Module>Reporting> TCP/IP Reporting>
Receiver Polling
Polling Time 1 minute GSM
NX-7002 Module>Reporting> TCP/IP Reporting>
Polling Time
Max Reports in 24 Hours 0 GSM
NX-7002 Module>Reporting> Report Attempts> Max
Reports in 24h
HomeText Control Disabled GSM
NX-7002 Module>Options> HomeText >System
Control>HomeText Control
Battery Change Allowed No KP
This Keypad>Keypad Features> Battery Change
Allowed
Case Tamper Yes KP This Keypad>Keypad Features>Case Tamper
F1 Functional Key
Alarm
Memory KP This Keypad>Function Keys>F1 Function
Hide PINs Yes KP
This Keypad>Keypad Features>Advanced
Options>Hide PINs
Beep on RF loss No KP
This Keypad>Keypad Features>Advanced
Options>Beep on RF loss
KP Shutdown allows Disarm Yes KP
This Keypad>Keypad Features>Advanced
Options>KP Shutdown allows Disarm (recommended)
KP Shutdown shows Clock Yes KP
This Keypad>Keypad Features>Advanced Options>
KP Shutdown shows Clock
Latch Faults Until Viewed No KP
This Keypad>Keypad Features>Advanced
Options>Latch Faults Until Viewed
Silent Keypad No KP This Keypad>Keypad Features>Silent Keypad