NetworX Version 3 Installation Manual
270
Table 51. Default EN 50131 settings
Option Setting Where Menu path
Clock Off CP
Control Panel>System Settings>Feature
Select>Clock>Use Cristal for Clock
Arm with Low Battery No CP
Control Panel>Partition Settings>Partition n>Feature
Select>Arming>Arm with Low Battery
Arm with Tamper Mem/FTC No CP
Control Panel>Partition Settings>Partition n>Feature
Select>Arming>Arm with Tamper Mem/FTC
Box Tamper Yes CP
Control Panel>System Settings>Feature
Select>Inputs>Box Tamper
Bypass - code required Yes CP
Control Panel>Partition Settings>Partition n>Feature
Select>Bypass>Code Required
EN Display Restrict Yes CP
Control Panel>System Settings>Feature
Select>Miscellaneous>EN Display Restrict
EN Mode Yes CP
Control Panel>System Settings>Feature
Select>Miscellaneous>EN Mode
Entry Time 30 s CP
Control Panel>Partition Settings>Partition
n>Timers>Entry Time 1/2
Exit Time 30 s CP
Control Panel>Partition Settings>Partition
n>Timers>Exit Time 1/ Exit Time 2
Forced Arming No CP
Control Panel>Inputs>Zone Types>Zone
Type n>Attributes>Force Armable (for all zone types)
Immediate Zone Restore Yes CP
Control Panel>System Settings>Feature
Select>Inputs>Immediate Zone Restore
Log Protection No CP
Control Panel>System Settings>Feature
Select>Miscellaneous>Log Protection
Quick Arm No CP
Control Panel>Partition Settings>Partition n>Feature
Select>Arming>Quick Arm
Tamper if Zone Lost No CP
Control Panel>Partition Settings>Partition n>Feature
Select>Miscellaneous>Tamper if Zone Lost
User Code Resets Tamper Memory Yes CP
Control Panel>System Settings>Feature
Select>Miscellaneous>User Code Resets Tamper
Memory
Swinger Shutdown 0 CP Control Panel>Inputs>Swinger Shutdown
Phone line cut fault delay
10
seconds CP
Control Panel>System Settings>Timers>
Communications>Phone Line Cut Delay
Autotest - in days Days CP
Control
Panel>Communications>Autotest>Hours/Days?
Autotest interval 1 CP Control Panel>Communications>Autotest>Interval
Keypress Tamper Yes CP
Control Panel>Partition Settings>>Partition n>Feature
Select>Keypads>Keypress Tamper
Open/Close event reporting Yes CP
Control Panel>Communications>Central
Station>Phone Numbers>Phone Number
n>Events>Arm/Disarm/Alarm>Opening/Closing
Exit Error reporting Yes CP
Control Panel>Communications>Reporting>Partition
Report>Exit Error
Siren sounds for expander trouble No CP
Control Panel>Outputs>Internal Siren>Sound
On>Expander Trouble
Failure To Communicate report
enabled Yes CP
Control Panel>Communications>Reporting>System
Reports>Communications>Fail to Communicate