EasyManuals Logo
Home>GE>Security System>NetworX V3

GE NetworX V3 User Manual

GE NetworX V3
286 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #270 background imageLoading...
Page #270 background image
NetworX Version 3 Installation Manual
270
Table 51. Default EN 50131 settings
Option Setting Where Menu path
Clock Off CP
Control Panel>System Settings>Feature
Select>Clock>Use Cristal for Clock
Arm with Low Battery No CP
Control Panel>Partition Settings>Partition n>Feature
Select>Arming>Arm with Low Battery
Arm with Tamper Mem/FTC No CP
Control Panel>Partition Settings>Partition n>Feature
Select>Arming>Arm with Tamper Mem/FTC
Box Tamper Yes CP
Control Panel>System Settings>Feature
Select>Inputs>Box Tamper
Bypass - code required Yes CP
Control Panel>Partition Settings>Partition n>Feature
Select>Bypass>Code Required
EN Display Restrict Yes CP
Control Panel>System Settings>Feature
Select>Miscellaneous>EN Display Restrict
EN Mode Yes CP
Control Panel>System Settings>Feature
Select>Miscellaneous>EN Mode
Entry Time 30 s CP
Control Panel>Partition Settings>Partition
n>Timers>Entry Time 1/2
Exit Time 30 s CP
Control Panel>Partition Settings>Partition
n>Timers>Exit Time 1/ Exit Time 2
Forced Arming No CP
Control Panel>Inputs>Zone Types>Zone
Type n>Attributes>Force Armable (for all zone types)
Immediate Zone Restore Yes CP
Control Panel>System Settings>Feature
Select>Inputs>Immediate Zone Restore
Log Protection No CP
Control Panel>System Settings>Feature
Select>Miscellaneous>Log Protection
Quick Arm No CP
Control Panel>Partition Settings>Partition n>Feature
Select>Arming>Quick Arm
Tamper if Zone Lost No CP
Control Panel>Partition Settings>Partition n>Feature
Select>Miscellaneous>Tamper if Zone Lost
User Code Resets Tamper Memory Yes CP
Control Panel>System Settings>Feature
Select>Miscellaneous>User Code Resets Tamper
Memory
Swinger Shutdown 0 CP Control Panel>Inputs>Swinger Shutdown
Phone line cut fault delay
10
seconds CP
Control Panel>System Settings>Timers>
Communications>Phone Line Cut Delay
Autotest - in days Days CP
Control
Panel>Communications>Autotest>Hours/Days?
Autotest interval 1 CP Control Panel>Communications>Autotest>Interval
Keypress Tamper Yes CP
Control Panel>Partition Settings>>Partition n>Feature
Select>Keypads>Keypress Tamper
Open/Close event reporting Yes CP
Control Panel>Communications>Central
Station>Phone Numbers>Phone Number
n>Events>Arm/Disarm/Alarm>Opening/Closing
Exit Error reporting Yes CP
Control Panel>Communications>Reporting>Partition
Report>Exit Error
Siren sounds for expander trouble No CP
Control Panel>Outputs>Internal Siren>Sound
On>Expander Trouble
Failure To Communicate report
enabled Yes CP
Control Panel>Communications>Reporting>System
Reports>Communications>Fail to Communicate