NetworX Version 3 Installation Manual
258
Appendix 1: Reporting codes in Contact ID or SIA
Table 41 Event codes lists the event codes sent for different reports (if enabled) when using Contact
ID or SIA formats. The numbers in brackets following the event is the number that is reported as the
zone number. If there are no parentheses, the zone is 0. An asterisk represents the first character from
the event code of the zone that is bypassed or in fault.
Table 41. Event codes
Report
Contact
ID SIA Report Contact ID SIA
AC fail 301 AT Panic 120 PA
AC fail restore 301 AR RAM Check Failure 303 IA
Alarm restore 000 R Recent closing (user number) 459 CR
Auto-test 602 RP RF FM jam 344 XQ
AUX Comm Fail 304 YN RF FM jam restore 344 XH
AUX Comm Fail Restore 304 YN RF jam 344 XQ
Auxiliary 2 panic 100 MA RF jam restore 344 XH
Bus Fault 307 IA ROM Check Failure 304 IA
Bus Fault Restore 307 NR Silent panic / B-alarm 130 BG
Bypass (zone number) 570 *B Siren tamper (device number) 321 YA
Bypass restore (zone
number)
570 *U
Siren tamper restore (device
number)
321 YH
Cancel (user number) 406 OC Sprinkler supervisory 200 SS
Closed with zones bypassed 456 CG Sprinkler supervisory restore 200 SR
Closing (user number) 401 CL Start download 411 RB
Control box tamper 137 TA Start of cross time 138 UA
Control box tamper restore 137 TR Start of listen in 606 LF
Control power up 602 RP Start program 627 LB
Duress 121 HA System Inactivity 304 YN
Early to open 451 OK Tamper 137 TA
End download 412 RS Tamper restore 137 TR
End program 628 LX Technician left 628 LX
Exit error (user number) 457 EE Technician on site 627 LB
Expander trouble (device
number)
333 ET Telephone fault 351 LT
Expander trouble restore
(device number)
333 ER Telephone fault restore 351 LR
Fail to communicate 354 RT Trouble (zone number) 380 *T
Faults Overwrite 408 CF Trouble restore (zone number) 380 *R
Forced Door 423 DF TX low battery 384 XT
Forced Door Restore 423 DR TX low battery restore 384 XR
Ground fault 310 GF Unknown Event 304 YN