NetworX Version 3 Installation Manual
248
14 = Incorrect access code
;
the
p
anel and file access code do not match RESULT
15 = Timeout
;
the re
q
uested command had no data exchan
g
e for 3 seconds RESULT
16 = Aborted
;
the
p
revious command was aborted b
y
attem
p
tin
g
another command RESULT
20= Transfer successful
;
the
p
revious read or write command was successful RESULT
Segment 2
Used to hold the file number for the requested read or write command. The only valid values are 1-4. This
segment is always set to 0 after any command to prevent accidentally overwriting an incorrect file.
Segments
3 - 6
Used to indicate the panel type stored in files 1-4 respectively.
Results 1 - 3 applies to the standard NetworX panels (NX-4 / NX-6 / NX-8).
Result 4 applies to the NX-8E panel.
Result 10 applies to the NX-4V2 panel
Result 11 applies to the NX-6V2 panel
Result 12 applies to the NX-8V2 panel
Result 15 applies to NetworX V3 panel.
Segment 7
Used to set the baud rate for the RS-232 connection (must match that of the DL-900 program). The valid
values are 0-7 and will be reset to 4 (9600 baud - factory default) if set incorrectly.
0= 600 Baud 2= 2400 Baud (2.4K) 4= 9600 Baud (9.6K) 6= 38400 Baud (38.4K)
1= 1200 Baud (1.2K) 3= 4800 Baud (4.8K) 5= 19200 Baud (19.2K) 7= 76800 Baud (76.8K)
Glossary
Location Term Definition
13 NX-586E A menu optional device used to interface the up/download
software directly to the control panel when the on board
serial port is not available.
13.1 Files A menu entry that groups the four programming memories
in the direct connect module.
13.1.1 File 1 A menu option that selects the programming memories
within the direct connect module. There are four possible
programming memories.
13.1.1.1 Panel Type A menu option that displays panel type information
currently stored in one of the four programming memory
files in the direct connect module.
13.1.1.2 Panel to File A menu option that copies a panel’s programming to one
of the programming memories in the direct connect
module. There are four possible programming memories in
the NX-586E.
13.1.1.3 File to Panel A menu option to copy programming memory from one of
the four memory locations contained in the direct connect
module, to the control panel.
13.2.1 Speed A menu option that sets the data communications speed
from the NX-586E direct connect module to the control
panel. This can be set from 600 baud to 76.8k baud. It is
recommended to use the default setting of 9600 baud.