Configuring the NX-1048 keypad features
General options
You can configure the LCD display, the keypad sounder and combination keys. The following
example configures the keypad so that all codes are displayed as stars rather than in digits. It also
configures the keypad sounder to beep when a wireless receiver does not report within the
supervision window.
1. Navigate with the ½¾ keys to This Keypad>Keypad Features and press OK.
2. Scroll to Display>Hide PINs>Yes and press OK.
3. The keypad beeps once to confirm the change and returns to Hide PINs.
4. Navigate with the ½¾ keys to Beep on RF loss>Yes and press OK.
5. The keypad beeps once to confirm the change and returns to Beep on RF loss.
You can also configure the keypad to hide system status. This is a system-wide option. It causes all
keypads to display a "Please Enter Your Code" prompt, power-on icon and "NOT OK to arm" icon
only, after 30 seconds of keypad inactivity. There is also an option to display time and date instead of
this prompt. In order to operate a blanked keypad you have to enter your user code (both in armed
and disarmed state).
1. Navigate with the ½¾ keys to Control Panel>System Settings>Feature
Select>Miscellaneous>KP Shutdown Mode and press OK.
2. Scroll to Enabled and press OK.
3. The keypad beeps once to confirm the change and returns to KP Shutdown Mode.
4. In order to display time and date instead of the "Please Enter Your Code" prompt,
navigate with the ½¾ keys to This Keypad>Keypad Features>Advanced Options>KP
Shutdown shows Clock>Enabled and press OK.
5. The keypad beeps once to confirm the change and returns to KP Shutdown shows Clock
There is an additional option to disarm the system directly from the blanked state, without "waking it
up" first, i.e. avoiding the necessity to enter the user code twice.
1. Navigate with the ½¾ keys to This Keypad>Keypad Features>Advanced Options and
press OK.
2. Scroll to KP Shutdown allows Disarm>Enabled and press OK.
3. The keypad beeps once to confirm the change and returns to KP Shutdown allows
Disarm.
Programming the function keys
The NX-1048 keypad has 8 function keys F1 to F8. The keys F1, F2, F7 and F8 can be configured to
perform any action listed in the
Table 19 Available function key actions. The other function keys -
F3, F4, F5 and F6 - have a permanent assigned function and cannot be configured. This way you can
create shortcuts for actions that otherwise require selecting a number of the user menu options or

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE NetworX V3 and is the answer not in the manual?

GE NetworX V3 Specifications

General IconGeneral
BrandGE
ModelNetworX V3
CategorySecurity System
LanguageEnglish

Related product manuals