7 - Fault finding
7.6
If an operator selects a configuration that has a , the Module Changed/Missing
window will appear, verifying that you want to load the configuration.
If you press , the configuration will be updated with the modules currently
being used.
ISOBUS Configuration Mismatch
If the HARDI® C2C Module is found but the data in
the Module and the selected configuration does
not match it will not be possible to proceed with
the operation selection.
This fault appears when the boom width and/or
the number of sections does not match in the
setup in the JobCom and the display.
Select another matching configuration or create a
new one with the same data in the JobCom and
display.
After changing the data in the JobCom the power
of the JobCom and ISOBUS C2C should be
powered On/Off to reload the new settings.
It might also be necessary to clear the virtual
terminal in the VT menu.
The selected configuration contains a
module that appears to have been replaced.
If this is the case, press accept. Otherwise,
press cancel and choose or create another
configuration.
Module Changed/Missing
Field Operation Wizard: Operating Configuration Selection
JD 4630, Hardi Commander
Equipment Name
Vehicle
Implement
JD 4630
Hardi Commander
Device Hardi
Hardi C2C Module: ISOBUS configuration mismatch
Container
Device
Main Tank
Boom Control
Norac UC5 Module