7 - Fault Finding
123
32 Illegal action No rinse water When pressing soft key for either BoomFlush,
FastFlush, MultiRinse while RinseTank is
calculated too empty for that program.
Key press does not start process.
Used by AutoWash/AutoFill.
Not enough rinse water for selected program.
AutoWash cannot be started.
33 Warning Steering not active Over speed
34 Waiting Start FlexCapacity pump Valves are positioned as in AutoWash table.
After press on soft key computer continues to
next step.
See also screen layouts.
Used by AutoWash/AutoFill
Double pump must be started to flush hoses.
Stop and start Double pump with hydraulic
lever, as Warning prompts you to.
35 Waiting Stop FlexCapacity pump Valves are positioned as in AutoWash table.
After press on soft key computer continues to
next step. See also screen layouts.
Used by AutoWash/AutoFill.
Double pump must be stopped to avoid
chemical in boom.
Stop and start Double pump with hydraulic
lever, as Warning prompts you to.
36 Waiting Pause
37 Warning PrimeFlow Comm. Fault
38 Warning Output failing to sect 1 Detected by H-bridge on I2C bus. Output failing to sect 1
39 Warning Output failing to sect 2 Detected by H-bridge on I2C bus. Output failing to sect 2
40 Warning Output failing to sect 3 Detected by H-bridge on I2C bus. Output failing to sect 3
41 Warning Output failing to sect 4 Detected by H-bridge on I2C bus. Output failing to sect 4
42 Warning Output failing to sect 5 Detected by H-bridge on I2C bus. Output failing to sect 5
43 Warning Output failing to sect 6 Detected by H-bridge on I2C bus. Output failing to sect 6
44 Warning Output failing to sect 7 Detected by H-bridge on I2C bus. Output failing to sect 7
45 Warning Output failing to sect 8 Detected by H-bridge on I2C bus. Output failing to sect 8
46 Warning Output failing to sect 9 Detected by H-bridge on I2C bus. Output failing to sect 9
47 Warning Output failing to sect 10 Detected by H-bridge on I2C bus. Output failing to sect 10
48 Warning Output failing to sect 11 Detected by H-bridge on I2C bus. Output failing to sect 11
49 Warning Output failing to sect 12 Detected by H-bridge on I2C bus. Output failing to sect 12
50 Warning Output failing to sect 13 Detected by H-bridge on I2C bus. Output failing to sect 13
51 Warning Output failing to bypass
52 Warning Nozzle valve air pressure too low
56 Warning Rinse tank not full
When MainTank has been filled and RinseTank is
empty.
Remember to re-fill rinse tank.
58 Warning Sections OFF
83 Reminder Aborted by Keypress
84 Warning AutoWash exception alarm #
88 Reminder Check filters & brakes
89 Reminder Grease points
90 Reminder Tighten bolts
91 Reminder Miscellaneous service
92 Reminder Check nozzles
94 Warning Rollover-protection activated
95 Changed Track is in auto
ID
(PG)
Type Fault Text at Display Criteria for Fault
Operations Disabled
Help Text

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hardi SMARTCOM ISOBUS UT SW A.2.2 Series and is the answer not in the manual?

Hardi SMARTCOM ISOBUS UT SW A.2.2 Series Specifications

General IconGeneral
BrandHardi
ModelSMARTCOM ISOBUS UT SW A.2.2 Series
CategoryFarm Equipment
LanguageEnglish

Related product manuals