7 - Fault Finding
124
96 Changed Track is Locked
97 Changed Reversing
98 Reminder AutoFill setpoint reached
99 Alarm PrimeFlow data cable weakness
100 Alarm Low Prime- Flow voltage
101 Warning PrimeFlow power cable defect
102 Warning PrimeFlow computer defect
103 Warning Fold with unlocked pendulum
105 Changed Agitation in auto
107 Warning Slant angle sensor fault Warning is active when 2.2.4.3 Slant mirror is
enabled and/or if 2.2.4.4 Slant in steps is
enabled.
The warning is generated, if the sensor signal
is less than0.2 Volt or exceeds 4.8 Volt.
Check sensor and cable on pendulum.
Disable HeadlandAssist.
Disable Slant in steps.
108 Alarm Boom height sensor fault
110 Warning Tank sensor fault
112 Changed Flat 1 Level 1 Hilly 5
113 Changed Flat 1 Level 2 Hilly 5
114 Changed Flat 1 Level 3 Hilly 5
115 Changed Flat 1 Level 4 Hilly 5
116 Changed Flat 1 Level 5 Hilly 5
117 Warning D-centre incorrect position
118 Warning Pendulum locking failed
119 Warning Pendulum release failed
120 Warning STOP! PENDULUM LOCKED!
121 Alarm Pendulum lock sensor
122 Warning Edit filled above content
123 Warning Folding not allowed
124 Reminder TODO_1
125 Reminder TODO_3
126 Reminder NO DILUTION Appears when dilution kit function is
activated, and no outputs are active.
Fluid systems works normally.
127 Reminder TANK DILUTION Appears when dilution kit function is
activated, and tank output is active.
Suction from rinse tank.
Flush tank through tank cleaning nozzles.
128 Reminder BOOM DILUTION Appears when dilution kit function is
activated, and Boom output is active.
Suction from rinse tank.
If nozzles are open - flush feed hoses.
If nozzles are closed - flush dump hose.
131 Warning Boom not in transport
132 Illegal action One function only
133 Illegal action Unfold inner wing
134 Illegal action Keep folding 1st outer wing
135 Illegal action Keep folding 2nd outer wing
ID
(PG)
Type Fault Text at Display Criteria for Fault
Operations Disabled
Help Text

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hardi SMARTCOM ISOBUS UT SW A.2.2 Series and is the answer not in the manual?

Hardi SMARTCOM ISOBUS UT SW A.2.2 Series Specifications

General IconGeneral
BrandHardi
ModelSMARTCOM ISOBUS UT SW A.2.2 Series
CategoryFarm Equipment
LanguageEnglish

Related product manuals