5.
Check Display Shield Area to show the shield area on the live view.
6.
Click Add to save the re detecon shield, and it will be listed in the list. You can select a region
and click Delete to delete it from the list. You can also enable the region or not.
7.
Click Save.
7.3 Perimeter Protecon
The funcon is used to detect whether there is any target breaking the perimeter protecon rules.
The opcal camera will track the target and the device will alarm when the perimeter protecon
rule is triggered.
7.3.1 Set Perimeter
Protecon Rules
The device can detect whether there is any target breaking the perimeter protecon rules. The
device will alarm when the rule is triggered.
Before You Start
Go to Conguraon → System → Maintenance → VCA Resource Type , select Temperature
Measurement + Perimeter
Protecon.
Steps
1.
Go to Conguraon → Perimeter Protecon → Rule .
2.
Check Intelligent Analysis.
3.
Oponal: Check Enable Fusion to view opcal and thermal image.
4.
Set perimeter protecon rules.
1) Click to add a new rule.
2) Enter the rule name, and click the drop down menu to select Rule Type.
Line Crossing
If any target moves across the
seng line, the alarm will be triggered. You can set the
crossing
direcon.
Intrusion
If any target intrudes into the pre-dened region longer than the set duraon, the alarm
will be triggered.
Region Entrance
If any target enters the pre-dened region, the alarm will be triggered.
Region Exing
If any target exits the pre-dened region, the alarm will be triggered.
3) Draw the
detecon rule.
Thermal Opcal Bi-spectrum Network Camera User Manual
58