MAINTENANCE
7-22
Check Hydraulic Oil Level --- daily
1. Park the machine on a solid level surface. Position
the machine with the arm cylinder fully retracted and
the bucket cylinder fully extended. Lower the bucket
and blade to the ground. Stop the engine.
2. Check oil level gauge (1) on the side of the hydraulic
oil tank. Oil must be at the specified level on the
gauge.
M1M7-05-024
M1MS-07-011
1