MAINTENANCE
7-34
E. FUEL SYSTEM
WARNING: Fuel is highly flammable. Handle fuel
with care. Keep open flame or sparks away from
fuel.
Refueling
After parking the machine on a level surface, check the
fuel level with fuel gauge (1) and level gauge (2). When
necessary to add fuel, remove fuel tank cap (3) and refill
fuel.
1. To avoid condensation, fill the tank at the end of each
day’s operation. Take care not to add more fuel than
the specified level.
Fuel Tank Capacity: 19.5 L (5.2 US gal)
2. After refilling fuel, close filler cover (4). Be sure to lock
the cover to prevent vandalism.
NOTE: Take care not to allow water and/or dirt to enter
the fuel system when refilling fuel.
Bleed Air from Fuel System
Air in the fuel system will cause the engine to start hard
and/or run roughly. Be sure to bleed air from the system
after replacing the fuel filter or draining the tank.
Automatic bleeding device is provided on this machine.
1. Confirm that the fuel level is more than one-half of the
tank capacity. If the fuel level is lower, automatic
bleeding device will not operate. Add fuel.
2. Turn the key switch ON and hold for 10 to 15
seconds.
3. Start the engine and check the fuel system for fuel
leaks.
M1MS-01-005
M1MS-07-005
M1MS-07-004
1
3
2
4
3

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hitachi ZAXIS 17U-2 and is the answer not in the manual?

Hitachi ZAXIS 17U-2 Specifications

General IconGeneral
BrandHitachi
ModelZAXIS 17U-2
CategoryExcavators
LanguageEnglish

Related product manuals