Galaxy Flex Installer Manual Appendix H: Resistance tables
255
Appendix H: Resistance tables
The following tables show the range of resistance for each option and operating state.
Option /Value
Tamper S/C
Low Res
Normal
High Res
Open
Fault
Masked
Tamper O/C
01 - 1k
0 - 800
800 - 900
900 - 1200
1200 - 1300
1300 - 12000
- 12000 - 19000
19000 - infinity
03 - 2k2 0 - 1800 1800 - 2000 2000 - 2500 2500 - 2700 2700 - 12000 - 12000 - 19000 19000 - infinity
05 - 4k7 0 - 3700 3700 - 4200 4200 - 5500 5500 - 6500 6500 - 12000 - 12000 - 22000 22000 - infinity
07 - 5k6 0 - 1400 1400 - 2800 2800 - 8400 8400 - 9800 9800 - 12600 - 12600 - 25000 25000 - infinity
09 - 3k3 0 - 2600 2600 - 3000 3000 - 4000 4000 - 4400 4400 - 12000 - 12000 – 22000
22000 - infinity
11 - 1k fault 0 - 800 800 - 900 900 - 1200 1200 - 1300 1300 - 3500 3500 - 4500 4500 - 19000 19000 - infinity
13 - 1k N/O - - 1200 - infinity
- 0 - 1200 - - -
15 - 4K7/2K2 0 - 800 800 - 1000 1000 - 4000 4000 - 5600 5600 - 8000 - 8000 - 20000 20000 - infinity
Table 12 Preset value limits (ohms) - double balanced
Option /Value
Tamper S/C
Low Res
Normal
High Res
Fault
Masked
Open
02 - 1k
0 - 800 800 - 900 900 - 1200 1200 - 1300 - 1300 -19000 19000 - infinity
04 - 2k2 0 - 1800 1800 - 2000 2000 - 2500 2500 - 2700 - 2700 - 19000 19000 - infinity
06 - 4k7 0 - 3700 3700 - 4200 4200 - 5500 5500 - 6500 - 6500 - 22000 22000 - infinity
08 - 5k6 0 - 1400 1400 - 2800 2800 - 8400 8400 - 9800 - 9800 - 25000 25000 - infinity
10 - 3k3 0 - 2600 2600 - 3000 3000 - 4000 4000 - 4400 - 4400 - 19000 19000 - infinity
12 - 1k fault 0 - 800 800 - 900 900 - 1200 1200 - 1300 1300 - 4500 4500 - 19000 19000 - infinity
14 – 0ohm N/C
- - 0 - 1200 - - - 1200 - infinity
16 - 2K 0 - 2000 2000 - 2200 2200 - 2700 2700 - 2900 - 2900 - 19000 19000 - infinity
Table 13 Preset value limits (ohms) - end of line