Omit Zones [11, Quick Menu 0] Galaxy Flex Installer Manual
48
Menu Options 11-19
Omit Zones [11, Quick Menu 0]
Use this option to remove (omit) zones from the system temporarily. Once a zone has been
omitted it does not generate an alarm condition (including tamper). Omitted zones are
reinstated automatically when the system is unset or reinstated manually when the zone omit
option is disabled.
On selecting the Omit Zones option, the first zone that has the omit attribute enabled is
displayed (refer to Program Zones [52]). If there are no omittable zones, then the message
NO ENTRIES is displayed.
Scroll to the zone you want to omit, and then press # to toggle the omit status. The display
indicates the new omit status.
Note: A zone is omitted from the system as soon as it is selected.
Repeat this process to omit more zones if required, and then do one of the following:
press ent to start the timed setting routine. The number of zo
nes omitted from the
system is displayed during the exit time countdown;
press esc to return to 11=OMIT ZONES without starting the setting routine.
On returning to the banner (normal or engineer) the keypad displays the message ZONES
OMITTED.
Outputs programmed as Zone Omit (mode programmed as reflex) are activated as soon as
the zone is omitted and remain active until the zone is reinstated.
Manually reintroduce omitted zones
Select the OMIT ZONES option.
Select the omitted zone to be reinstated, and then press # to toggle the omit status of the
required zone. The display indicates the new omit status.
Normal Setting with omitted zones
Initiate the full or part setting routine. The system starts to set, and the display indicates that
zones have been omitted. The zone remains omitted until the system is unset.
Timed Set [12]
This option starts the setting routine. The entry/exit horns emit the expiry warning using the
p
rogrammed exit time (0-300 seconds). The system sets at the end of the exit time or earlier
if a final zone is opened and closed, key 0 is pressed if programmed as an exit terminator, or
if a push-set terminator is operated. The option displays the time remaining until the system
sets or the number of open zones preventing the system from setting. Opening a zone during
the exit routine resets the exit timer. Pressing esc prior to the system setting aborts the
se
tting routine.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Galaxy Flex V3 Series and is the answer not in the manual?

Honeywell Galaxy Flex V3 Series Specifications

General IconGeneral
BrandHoneywell
ModelGalaxy Flex V3 Series
CategorySecurity System
LanguageEnglish

Related product manuals