Galaxy Flex Installer Manual Part Set [13]
49
Note: The factory default setting allows the timed setting routine to be initiated by entering
a valid type 1 user code (or above) and then pressing A. By default the A key is
assigned to the Timed Set function. The A key can be reprogrammed by the engineer
to perform another function, or to start the setting routine without a code being
entered.
Part Set [13]
This option operates in a similar way to the Timed Set option with the exception that only
those zones that have the part or night set attribute enabled are set (refer to Program Zones
[52]). All zones have the part and night attribute enabled by default. Therefore selecting Part
Set from the factory will set all zones. To exclude zones from the part or night set, disable
the Part and/or Night attribute as appropriate.
Note: The factory default setting allows the part setting routine to be initiated by entering a
valid type 1 (or above) user code and pressing B. By default the B key is assigned to
the Part Set function. The B key can be reprogrammed by the engineer to perform
another function, or to start the part setting routine without a code being entered.
Forced Set [14]
Option not available.
Chime [15, Quick Menu 1]
The Chime option allows the user to switch the chime facility on and off (1 = On, 2 = Off).
A
ny zones that have the chime attribute enabled (refer to Program Zones [52])
momentarily operate entry/exit horns when opened, and two long tones are emitted.
Instant Set [16]
Selecting this option immediately sets all zones. There is no sounder or exit time.
Note: Zones must be closed to allow the system to set. If any zones are open the exit time
reset feature (detailed previously) is activated.
Silent Part [17]
Selecting this option sets all zones that have the part attribute enabled. It starts a normal
timed exit procedure but exit sounders are not activated. In the event of an alarm occurring
during a Silent Part set (e.g. fire alarm), normal operation will be re-instated.
When group mode is enabled (option [63.1]), no other group setting options are affected.
Note: Zones must be closed to allow the system to silent set. If any zones are open, then
the Exit Time Reset feature (detailed previously) is activated.
Unsetting results in a double beep.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Galaxy Flex V3 Series and is the answer not in the manual?

Honeywell Galaxy Flex V3 Series Specifications

General IconGeneral
BrandHoneywell
ModelGalaxy Flex V3 Series
CategorySecurity System
LanguageEnglish

Related product manuals