EasyManuals Logo
Home>Honeywell>Security System>Galaxy Flex V3 Series

Honeywell Galaxy Flex V3 Series User Manual

Honeywell Galaxy Flex V3 Series
258 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #37 background imageLoading...
Page #37 background image
Galaxy Flex Installer Manual Default codes
37
Default codes
The system provides three default codes: Manager, Engineer and Remote User.
Flex model Total No. of
Codes
Manager Engineer Remote User
Default PIN User No. Default PIN User No. Default PIN User No.
FX100 100 1234 98 112233 99 543210 100
FX50 50 1234 48 112233 49 543210 50
FX20 25 1234 23 112233 24 543210 25
Keypad menu timeout
If you do not use the keypad for 5 minutes the system reverts to displaying the banner text.
This does not apply if you are logged in as Engineer (type 7).
Note: In the Walk Test option the timeout is 20 minutes if no zones are tested or no keys
are pressed. In 66=PRE-CHECK the timeout is 20 minute after the last zone has
been activated.
Engineer Mode
To program the control panel, the system must be in engineering mode, allowing access to
m
enu options 50=ENGINEER 1, 60=ENGINEER 2 and 70=ENGINEER 3.
If you are setting up and programming a control panel prior to handover, use the following
procedure to access engineering mode.
To enter Engineer Mode:
1. Enter the default manager code, and then press ent.
2. Press 48 ent 1 ent 1 ent 1 ent to enable Engineer Mode. You have 5 minutes to carry
out the next step.
3. Press esc repeatedly to return to the Honeywell banner.
4. Enter the default engineer code, and then press ent.
After handover the codes should have been changed and you will need to get a manager or
other type 6 user to carry out steps 1 and 2. See Engineer Access [48] for more details.
Alternatively any user can present a prox tag to a Keyprox keypad, and then press
and 3
simultaneously.
On accessing engineering mode, any group that is set becomes inaccessible. Set groups
cannot be assigned to zones, outputs and any other functions permitting group allocation.
When the engineer code is entered three things happen:
All system tampers become isolated.
You gain access to the full menu.
The banner message is changed to indicate engineer mode.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Galaxy Flex V3 Series and is the answer not in the manual?

Honeywell Galaxy Flex V3 Series Specifications

General IconGeneral
BrandHoneywell
ModelGalaxy Flex V3 Series
CategorySecurity System
LanguageEnglish

Related product manuals