Galaxy Flex Installer Manual Additional programming
29
Additional programming
Use this section as a quick reference to some of the functions you may wish to program or
modify.
Parameters (51 ent)
Entry Time (05 ent) – defines the user unsetting time
Exit Time (04 ent) – defines user exit time before system set
Bell Time (01 ent) – bell sounding time (default = 15 mins)
Bell Delay (02 ent) – delay bell activation for up to 20 mins
Reset Levels (65 ent) – defines which user type can reset specific faults
Confirm (55 ent) – controls how confirmed alarms are generated
Keypad Access (54 ent) – disable unset on entry
RF
Parameters (60 ent) – access these options:
RF Address (1 ent) – enable and disable wireless virtual RIO addresses
RF Fob PA (2 ent) – enable to allow users to program the Panic Alert function of
wireless keyfobs
Program zones (52 ent + Zone Address)
Function (01 ent) – assign zone function
Descriptor (02 ent) – name a zone (up to 16 characters)
Part (05 ent) – zone included in a part or night setting option
Omit (04 ent) – zone omitted when using an omit function
Chime (03 ent) – opened zones cause momentary chime when system unset
Group (10 ent) – assign zone to a group, if enabled
Resistance Select (09 ent) – change pre-defined resistance for the selected zone
Activity Monitor (08 ent) – check zone activity
RF Options (11 ent) – access these options:
Serial No. (1 ent) – manual or self-learn entry of wireless device serial number
Loop No. (2 ent) – loop number of multiple input wireless devices
Su
pervision (3 ent) – enable for periodic device supervision
Au
to Reset (4 ent) – enable to force zone to automatically close after five seconds
Signal Level (5 ent) – display device signal level