92 Xenon XP User Guide
In-Stand Sensor Mode
Note: The In-Stand Sensor feature only applies to Xenon XP 1950g, 1950h, 1952g, and
1952h products. It does not apply to the Xenon XP 1952-BF products.
This feature senses when the scanner is removed from the stand and tells it to
begin manual triggering. When Sensor On is enabled, the scanner defaults to
Manual Trigger Mode when it is removed from the stand. Default = Sensor On.
Note: If you are taking images (see Imaging Commands beginning on page 215), you must
set the In-Stand Sensor to Off.
Poor Quality Codes
Poor Quality 1D Codes
This setting improves the scanner’s ability to read damaged or badly printed linear
barcodes. When Poor Quality 1D Reading On is scanned, poor quality linear
barcode reading is improved, but the scanner’s snappiness is decreased, making it
less aggressive when reading good quality barcodes. This setting does not affect
2D barcode reading. Default = Poor Quality 1D Reading Off.
Left of
Presentation Centering
Window
Right of Presentation
Centering Window
Poor Quality 1D Reading On