EasyManuals Logo

Honeywell Xenon XP 1952g User Manual

Honeywell Xenon XP 1952g
332 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #258 background imageLoading...
Page #258 background image
240 Xenon XP User Guide
scanner. This setting is changed by using the BT_NAM command,
which accepts alphanumeric values. If the name is not known, a wild-
card (*) can be used :*
Note: Since the base stores all work group settings and transfers to them to scanner once
they are linked, changes are typically done to the base and not to the scanner.
Tag A 3 character case-insensitive field that identifies the desired menu
command group. For example, all RS232 configuration settings are
identified with a Tag of 232.
SubTag A 3 character case-insensitive field that identifies the desired menu
command within the tag group. For example, the SubTag for the
RS232 baud rate is BAD.
Data The new value for a menu setting, identified by the Tag and SubTag.
Storage A single character that specifies the storage table to which the com-
mand is applied. An exclamation point (!) performs the command’s
operation on the device’s volatile menu configuration table. A period
(.) performs the command’s operation on the device’s non-volatile
menu configuration table. Use the non-volatile table only for semi-
permanent changes you want saved through a power cycle.
Query Commands
Several special characters can be used to query the device about its settings.
^ What is the default value for the setting(s).
> What is the PAP sub command.
Note: When using the >, all other commands will return NAK.
? What is the device’s current value for the setting(s).
* What is the range of possible values for the setting(s). (The device’s
response uses a dash (-) to indicate a continuous range of values. A
pipe (|) separates items in a list of non-continuous values.)
:Name: Field Usage (Optional)
This command returns the query information from the scanner.
Tag Field Usage
When a query is used in place of a Tag field, the query applies to the entire set of
commands available for the particular storage table indicated by the Storage field
of the command. In this case, the SubTag and Data fields should not be used
because they are ignored by the device.

Table of Contents

Other manuals for Honeywell Xenon XP 1952g

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell Xenon XP 1952g and is the answer not in the manual?

Honeywell Xenon XP 1952g Specifications

General IconGeneral
TypeHandheld bar code reader
Sensor type-
Scanner type1D/2D
Pitch reading angle-45 - 45 °
Light levels (direct sunlight)0 - 100000 lx
Linear (1D) barcodes supportedCode 128, Code 39, U.P.C.
Optical sensor resolution (W x H)1240 x 800 pixels
2D (matrix & stacked) barcodes supportedData Matrix, PDF417, QR Code
Battery life14 h
Charging time4.5 h
Battery capacity2400 mAh
Power source typeBattery
Number of reads per charge50000
Wireless range10 m
Bluetooth version4.2
Operating frequency2400 MHz
Standard interfacesBluetooth, USB
Connectivity technologyWired & Wireless
Product colorBlack
LED indicatorsYes
Built-in displayNo
Protection featuresBump resistant
Storage temperature (T-T)-40 - 70 °C
Operating temperature (T-T)0 - 50 °C
Operating relative humidity (H-H)0 - 95 %
Harmonized System (HS) code84716070
Weight and Dimensions IconWeight and Dimensions
Depth99 mm
Width64 mm
Height165 mm
Weight220 g

Related product manuals