Do you have a question about the Honeywell Xenon XP 1952g and is the answer not in the manual?
Type | Handheld bar code reader |
---|---|
Sensor type | - |
Scanner type | 1D/2D |
Pitch reading angle | -45 - 45 ° |
Light levels (direct sunlight) | 0 - 100000 lx |
Linear (1D) barcodes supported | Code 128, Code 39, U.P.C. |
Optical sensor resolution (W x H) | 1240 x 800 pixels |
2D (matrix & stacked) barcodes supported | Data Matrix, PDF417, QR Code |
Battery life | 14 h |
Charging time | 4.5 h |
Battery capacity | 2400 mAh |
Power source type | Battery |
Number of reads per charge | 50000 |
Wireless range | 10 m |
Bluetooth version | 4.2 |
Operating frequency | 2400 MHz |
Standard interfaces | Bluetooth, USB |
Connectivity technology | Wired & Wireless |
Product color | Black |
LED indicators | Yes |
Built-in display | No |
Protection features | Bump resistant |
Storage temperature (T-T) | -40 - 70 °C |
Operating temperature (T-T) | 0 - 50 °C |
Operating relative humidity (H-H) | 0 - 95 % |
Harmonized System (HS) code | 84716070 |
Depth | 99 mm |
---|---|
Width | 64 mm |
Height | 165 mm |
Weight | 220 g |
Provides installation and programming instructions for Xenon XP scanners and bases.
Steps to follow after opening the shipping carton containing the product.
Instructions for connecting the scanner or cordless base to a computer's USB port.
Connects the scanner between the keyboard and PC for data output.
Instructions for connecting the scanner to the terminal/computer via an RS232 serial port.
Connects the scanner or cordless base for an IBM POS terminal interface.
Details on how to mount the charge base horizontally or vertically.
Explains how to use the scanner's viewfinder and aiming beam for effective scanning.
Restricts menu code scanning and allows setting/resetting custom defaults.
Explains how to program the system for the desired interface.
Uses Plug and Play barcodes for instant scanner setup for common interfaces.
Programs the scanner for IBM PC AT and compatibles keyboard wedge interface with USA keyboard.
Allows scanner operation with laptops in parallel with the integral keyboard.
Programs the scanner for connection to a PC or terminal's serial port.
Programs the scanner for an IBM POS terminal interface.
Programs scanner for various USB interfaces like SurePos, PC/Mac, HID, and Serial.
Controls CTS/RTS emulation and ACK/NAK mode for serial communication.
Programs scanner for various terminal emulations.
Programs scanner for Honeywell bioptic and Datalogic Magellan auxiliary ports.
Allows changing the default US keyboard layout to other national layouts.
Modifies keyboard wedge features, style, case conversion, and control character output.
Configures RS232 parameters including Baud Rate, Time-Out, Handshake, and Flow Control.
Settings for communication between Honeywell scanners and bioptic scanners.
Explains the function of the base/Access Point in providing the link between scanner and host.
Steps to establish a wireless link between the scanner and its base or Access Point.
Procedure to replace a scanner and describes feedback for successful scanning and data acknowledgment.
Details on programming scanner, base, and Access Point settings, and RF module operation.
Explains scanner states (Out of Range, Relinking) and Batch Mode operations.
How the page button interacts with Presentation Modes and timeout settings.
Details on the integrated battery, recommendations, and safety precautions.
Explains the meaning of scanner and base LEDs and beep sequences.
Configures base indicators and low power alerts for battery-free scanners.
Reboots scanner and enables/disables scanning while in the base cradle.
Configures base charge modes and scanner link modes.
Manages alarms when scanner is out of range and configures alarm sound types.
Sets scanner power time-out timer and configures flexible power management.
Manages Bluetooth pairing, PIN codes, network activity, and host acknowledgment.
Controls scanner connection attempts and idle time between attempts.
Validates barcode data and manages host acknowledgments.
Configures power-up beep for scanner and base.
Controls beep, click, and vibration responses for various scanner events.
Programs LED indicator on/off for a good read.
Sets minimum time before scanner can read another barcode.
Configures manual trigger modes, toggle functionality, and timing.
Activates scanner via serial commands and sets read time-out.
Uses ambient light, controls presentation LED behavior, and narrows field of view for barcode reading.
Programs symbology priority and defines output sequences for scanned symbols.
Programs scanner and base for silent or quiet operation using combination codes.
Adjusts visual (LED) indicators and volumes for linking, scanning, paging, and alarms.
Explains prefix and suffix characters sent before and after scanned data.
Step-by-step guide to adding or clearing prefixes/suffixes for symbologies.
Transmits ASCII control characters or disables them.
Slows data transmission to increase integrity by adding delays.
Explains changing scanner output by inserting characters at specific points.
Guides through showing, adding, clearing, and saving data formats.
Lists commands for creating and managing output sequences.
Enables/disables symbologies and sets valid reading length for barcode data.
Configures Codabar start/stop characters, check character, concatenation, and message length.
Configures Code 39 On/Off, start/stop, check character, message length, and append.
Settings for Code 32 Pharmaceutical and Full ASCII interpretation.
Configures Interleaved 2 of 5 check digit, message length, and FEBRABAN decode.
Configures NEC 2 of 5 check digit and message length.
Configures Code 93 On/Off, message length, append, and code page.
Configures Straight 2 of 5 Industrial and IATA symbologies.
Configures Matrix 2 of 5 On/Off and Message Length.
Configures Code 11 On/Off, check digits, and message length.
Configures Code 128 On/Off, ISBT concatenation, redundancy, message length, append, and code page.
Configures GS1-128, Telepen, UPC-A, Addenda, Coupon GS1 DataBar, UPC-E0, UPC-E1, EAN/JAN-13 settings.
Configures Trioptic Code, Codablock A, and Codablock F.
Configures PDF417 and MacroPDF417 symbologies.
Configures MicroPDF417, GS1 Composite Codes, and UPC/EAN Version.
Configures GS1 emulation modes and TCIF Linked Code 39.
Configures QR Code and DotCode symbologies.
Configures Digimarc Barcode decoding and Data Matrix settings.
Decodes DPM barcodes and configures MaxiCode.
Configures Aztec Code and Chinese Sensible (Han Xin) Code.
Lists allowed 2D postal codes and combinations.
Lists linear postal codes and configurations for China Post and Korea Post.
Imaging commands with modifiers send single-use instructions for image capture.
Explains how multiple modifiers and commands are issued in sequence.
Captures images and applies modifiers to change image look.
Transmits the last stored image using the IMGSHP command.
Configures size, location, and output of signature capture area relative to barcode.
Scanner uses RF_DID menu command to receive imaging commands from applications.
Temporarily turns on transmission of Code I.D. before decoded symbology.
Outputs current software revision, serial number, and product information.
Scans programming code to display content and perform function.
Open system architecture for creating applications residing on the scanner.
Enables or disables apps like Decoding and Formatting by scanning barcodes.
Provides PC-based functions for scanner programming, firmware upgrades, and parameter changes.
Erases all settings and resets scanner to factory defaults.
Defines conventions and syntax for menu commands.
Explains special characters for querying device settings and field usage.
Activates and deactivates the scanner using serial trigger commands.
Restores custom default settings to the scanner using a serial command.
Mechanical, electrical, and environmental specifications for corded scanners.
Mechanical, electrical, environmental, and radio specs for cordless scanners.
Mechanical, electrical, radio, and environmental specs for charge bases.
Charts showing typical and guaranteed performance for symbologies at various distances.
Pin assignments for Keyboard Wedge, Serial Output, USB, and RS485 connectors.
Services to be performed only by an authorized service center.
Describes periodic checks for dependable operation and cleaning the scanner.
Info on special housings and inspecting interface cables for damage.
Procedures for replacing scanner cables and cordless system batteries.
Guide for common corded scanner issues like power, aimer, and reading problems.
Guidelines for diagnosing and resolving cordless base and scanner issues.
Charts listing symbologies with AIM and Honeywell identifiers.
Displays sample barcodes for various symbologies.
Provides barcodes for programming scanner settings.