Overview 7
Overview
Important safety information
NOTE: The HP Intelligent Power Distribution Unit (iPDU) is intended for use only with
information technology equipment (ITE) loads in racks or similar computer room applications.
Extension Bars ship with some kits. These Extension Bars are designed for use with
Compaq/HP Power Distribution Core Units and HP Uninterruptible Power Systems (UPSs). The
Extension Bars can be used with other power sources, provided that the source includes
branch circuit overcurrent protection not exceeding 20 A.
WARNING: To reduce the risk of personal injury from electric shock, do not remove the
cover. There are no field-serviceable or user-serviceable components inside.
WARNING: A risk of personal injury from electric shock and hazardous energy levels exists.
The installation of options and routine maintenance and service of this product must be
performed by individuals who are knowledgeable about the procedures, precautions, and
hazards associated with AC power products.
Follow these safety precautions when connecting multiple hardware components to power sources.
WARNING: To reduce the risk of personal injury or damage to the equipment:
Plug the input power cord into a grounded (earthed) electrical outlet that is located near
the equipment and is easily accessible.
Be sure that the load products connected to the HP Intelligent Power Distribution Unit
(iPDU) are adjusted for, or otherwise capable of operation from the same line voltage
supplying the iPDU. Failure to verify the voltage can lead to severe equipment damage.
Do not overload the iPDU. The total input current rating of all equipment connected to each
output cannot exceed the total output rating marked on the iPDU.
WARNING: To reduce the risk of personal injury from high-leakage current, verify earth
connection before connecting the power supply.
The summation of input power for multiple pieces of information technology equipment
through the use of power products can result in high-leakage currents.
If the total system leakage current for a system of components exceeds 3.5 mA:
The use of a detachable input power cord is prohibited.
The input power cord must be securely attached, and it should be connected to the AC
mains by hardwiring or through the use of a non-residential, industrial-style plug that
maintains positive earth connection.
If the total system leakage current through the ground conductor exceeds 5% of the input
current per line under normal operating conditions, the system loads should be divided
among multiple power connections.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP Intelligent Power Distribution Unit and is the answer not in the manual?

HP Intelligent Power Distribution Unit Specifications

General IconGeneral
BrandHP
ModelIntelligent Power Distribution Unit
CategoryPortable Generator
LanguageEnglish

Related product manuals