C-36
Troubleshooting
Using the Event Log for Troubleshooting Switch Problems
Example of Event Counter Operation
Suppose the switch detects the following after a reboot:
■ Three duplicate instances of the PIM “Send error” during the first log
throttle period for this event
â–  Five more instances of the same Send error during the second log throttle
period for this event
â–  Four instances of the same Send error during the third log throttle period
for this event
In this case, the duplicate message would appear three times in the Event Log
(once for each log throttle period for the event being described), and the
Duplicate Message Counter would increment as shown in table C-4. (The same
operation would apply for messages sent to any configured SNMP trap
receivers.)
Table C-4. How the Duplicate Message Counter Increments
Instances
During 1st Log
Throttle Period
Instances
During 2nd Log
Throttle Period
Instances
During 3rd Log
Throttle Period
Duplicate
Message
Counter*
3
1
5 4
49
*This value always comprises the first instance of the duplicate
message in the current log throttle period plus all previous occurrences
of the duplicate message occurring since the switch last rebooted.