EasyManuals Logo

HP ProLiant Gen9 User Manual

HP ProLiant Gen9
410 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #100 background imageLoading...
Page #100 background image
HP ProLiant Gen9 power fault LEDs 100
HP ProLiant Gen9 power fault LEDs
Power fault LEDs
When the front panel LEDs are flashing simultaneously, a power fault has occurred. The following table
provides a list of power fault LEDs, and the subsystems that are affected. Not all power faults are used by all
servers.
Subsystem LED behavior
System board
1 flash
Processor
2 flashes
Memory
3 flashes
Riser board PCIe slots
4 flashes
FlexibleLOM
5 flashes
Removable HP Flexible Smart Array
controller/Smart SAS HBA controller
6 flashes
System board PCIe slots
7 flashes
Power backplane or storage backplane
8 flashes
Power supply
9 flashes

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProLiant Gen9 and is the answer not in the manual?

HP ProLiant Gen9 Specifications

General IconGeneral
Product LineProLiant
GenerationGen9
ChipsetIntel C610 series
Expansion SlotsPCIe 3.0
StorageSATA, SAS, SSD
Network1GbE, 10GbE
ManagementHP iLO (Integrated Lights-Out)
Power SupplyFlexible slot, hot-plug power supplies
Form FactorRack, Tower, Blade
ProcessorIntel Xeon E5-2600 v3/v4 series
RAIDHP Smart Array controllers