HP Smart Array errors 123
Log message: The Smart Array controller <controller name / slot information> is not
redundant because it is of a different firmware revision than its' partner
controller.
Message Id: 24645
Severity: Error
Log message: The Smart Array controller <controller name / slot information> is not
redundant because it is using a different cache size than its' partner controller.
Message Id: 24646
Severity: Error
Log message: The Smart Array controller <controller name / slot information> is not
redundant because its' partner controller has reported a cache failure.
Message Id: 24647
Severity: Error
Log message: The Smart Array controller <controller name / slot information> is no
longer redundant because this controller and its' partner controller can no longer
see all the physical drives.
Message Id: 24648
Severity: Error
Log message: The Smart Array controller <controller name / slot information> is no
longer redundant because one or more drives has been determined not to be able
to support redundant controller operations.
Message Id: 24649
Severity: Warning
Log message: The Smart Array controller <controller name / slot information> is no
longer redundant because an expand operation is in progress. The controller will
become redundant once again once the expand operation has completed.
Message identifiers 24650-24674
Message Id: 24650
Severity: Informational
Log message: SnapShot ID <ID number> of logical drive <logical drive number> on
<external specification> array controller <controller name / slot information>
has been created.
<external specification> values:
• “the external controller attached to”
• ""
Message Id: 24651
Severity: Error
Log message: SnapShot ID <ID number> of logical drive <logical drive number> on
<external specification> array controller <controller name / slot information>
failed and has been deleted.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProLiant Gen9 and is the answer not in the manual?

HP ProLiant Gen9 Specifications

General IconGeneral
Product LineProLiant
GenerationGen9
ChipsetIntel C610 series
Expansion SlotsPCIe 3.0
StorageSATA, SAS, SSD
Network1GbE, 10GbE
ManagementHP iLO (Integrated Lights-Out)
Power SupplyFlexible slot, hot-plug power supplies
Form FactorRack, Tower, Blade
ProcessorIntel Xeon E5-2600 v3/v4 series
RAIDHP Smart Array controllers