EasyManuals Logo

HP ProLiant Gen9 User Manual

HP ProLiant Gen9
410 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #184 background imageLoading...
Page #184 background image
HP Onboard Administrator errors 184
OA: WARNING: DNS resolution has failed. This will impair OA operation
significantly.
OA: WARNING: The DNS resolution for is slow, one or more DNS servers may be down.
This will impair OA operation.
OA: The DNS resolution is working again.
OA: WARNING: DNS resolution has failed. This will impair OA operation
significantly.
OA: WARNING: The DNS resolution is slow, one or more DNS servers may be down.
This will impair OA operation.
OA: The DNS resolution is working again.
OA: Restarted the System Logger.
Log type: LOG_CRIT, Failure type: SW
OA: Onboard Administrator %d domain name change failed.
Log type: LOG_ALERT, Failure type: SW
OA: Cannot start Network Monitoring.
LCD log messages
Log type: LOG_ERR, Failure type: SW
OA: Blade [value:bladeNumber]: KVM access denied.
OA: Consume SEMV post failed errno [value]
OA: Error creating fifo SAVEPNG_FIFO ". No screenshot thread available"
OA: Error opening fifo SAVEPNG_FIFO ". No screenshot thread available"
OA: KVM Bay [value:bladeNumber] - All HTTP sessions to ILO are full. Wait a few
seconds and try again.
OA: KVM Bay [value:bladeNumber] - Connection to blade failed.
OA: KVM Bay [value:bladeNumber] - Connecting to blade failed because the blade
is powered off.
OA: KVM Bay [value:bladeNumber] - Could not connect. Error([value]).
OA: KVM Bay [value:bladeNumber] - Could not connect. If error persists reboot
the OA.
OA: KVM Bay [value:bladeNumber] - Could not create thread.
OA: KVM Bay [value:bladeNumber] - Disconnected from blade. Bad getmore
OA: KVM Bay [value:bladeNumber] - Disconnected from blade. Bad next state
detected.
OA: KVM Bay [value:bladeNumber] - Disconnected from blade. Bad state transition
detected.
OA: KVM Bay [value:bladeNumber] - Disconnected from blade. Exit state detected.
OA: KVM Socket connect error [value] ([value]) to ILO addr
[value:Address]:[value:port]
OA: KVM Socket creation error [value] ([value]) to ILO addr[value:Address]
OA: Mutex SEMV post failed errno [value]
OA: Mutex SEMV wait failed errno [value]

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProLiant Gen9 and is the answer not in the manual?

HP ProLiant Gen9 Specifications

General IconGeneral
Product LineProLiant
GenerationGen9
ChipsetIntel C610 series
Expansion SlotsPCIe 3.0
StorageSATA, SAS, SSD
Network1GbE, 10GbE
ManagementHP iLO (Integrated Lights-Out)
Power SupplyFlexible slot, hot-plug power supplies
Form FactorRack, Tower, Blade
ProcessorIntel Xeon E5-2600 v3/v4 series
RAIDHP Smart Array controllers