Microsoft Windows Event ID and SNMP traps 335
Log Message: Could not write the registry subkey: “%1”. This error can be caused by a corrupt registry or a
low memory condition. Rebooting the server may correct this error.
Event identifier: cpqstmsg.dll - 1285 (Hex)0x84350505 (Service Event)
Log Severity: Warning (2)
Log Message: Could not write the registry subkey: “%1”. This error can be caused by a corrupt registry or a
low memory condition. Rebooting the server may correct this error.
Event identifier: cpqstmsg.dll - 1294 (Hex)0x8435050e (Service Event)
Log Severity: Warning (2)
Log Message: Unsupported storage system. The ProLiant storage system %1 is unsupported by this version of
the Storage Agents. Upgrade the agents to the latest version.
Event Identifiers 1343-4613
Event identifier: cpqstmsg.dll - 1343 (Hex)0x8435053f (Service Event)
Log Severity: Warning (2)
Log Message: Duplicate SCSI port found in slot %1. The current system ROM may not support this SCSI
controller. You may need to update your system ROM.
Event identifier: cpqstmsg.dll - 1344 (Hex)0x84350540 (Service Event)
Log Severity: Warning (2)
Log Message: A version mismatch has been detected with the SCSI device monitor driver (CPQSDM.SYS).
The current driver version is %1. Cause: You may not have rebooted after a Storage Agents upgrade. Always
reboot the system after installing agents.
Event identifier: cpqstmsg.dll – 1346 (Hex) 0x84350540 (Service Event)
Log Severity: Warning (2)
Log Message: The SCSI controller on port %1 has been omitted. The SCSI Agent could not get the slot data
for the controller.
Event identifier: cpqstmsg.dll - 1792 (Hex)0x84350700 (Service Event)
Log Severity: Warning (2)
Log Message: The SNMP Agent is unable to generate traps due to an error during initialization.
Cause: Check to Be sure that the SNMP service is running. Reinstalling the agents may fix this error.
Event identifier: cpqstmsg.dll - 1795 (Hex)0x84350703 (Service Event)
Log Severity: Warning (2)
Log Message: The SNMP Agent is older than other components. The SNMP Agent is older than the other
components of the Storage Agents. Reinstall the entire Storage Agents package to correct this error.
Event identifier: cpqstmsg.dll - 1796 (Hex)0x84350704 (Service Event)
Log Severity: Warning (2)
Log Message: The %1 Agent is older than other components. The %1 Agent is older than the other
components of the Storage Agents. Reinstall the entire Storage Agents package to correct this error.
Event identifier: cpqstmsg.dll - 1800 (Hex)0x84350708 (Service Event)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProLiant Gen9 and is the answer not in the manual?

HP ProLiant Gen9 Specifications

General IconGeneral
Product LineProLiant
GenerationGen9
ChipsetIntel C610 series
Expansion SlotsPCIe 3.0
StorageSATA, SAS, SSD
Network1GbE, 10GbE
ManagementHP iLO (Integrated Lights-Out)
Power SupplyFlexible slot, hot-plug power supplies
Form FactorRack, Tower, Blade
ProcessorIntel Xeon E5-2600 v3/v4 series
RAIDHP Smart Array controllers