HP Smart Array errors 106
1 - Amber 2 - Green 3 - Green Interpretation
Off
On Off The current backup is complete with no errors.
Flashing once
per second
Flashing once
per second
Off The current backup failed, and data has been lost.
Flashing once
per second
Flashing once
per second
On A power error occurred during the previous or current
boot. Data may be corrupt.
Flashing once
per second
On Off An overtemperature condition exists.
Flashing twice
per second
Flashing twice
per second
Off The battery is not connected to the system board.
Flashing twice
per second
Flashing twice
per second
On The battery has been charging for 10 minutes, but has
not reached sufficient charge to perform a full backup.
On
On Off The current backup is complete, but power fluctuations
occurred during the backup.
On
On On The cache module microcontroller has failed.
Smart Array Windows Event Log messages
Message identifiers 24578-24599
Message Id: 24578
Severity: Informational
Log message: The HP Smart Array SAS/SATA event notification service version %1.
Message Id: 24579
Severity: Informational
Log message: An event queue overflow has occurred for the array controller
<controller name / slot information>. At least one event has been lost. This
controller will only queue up to 100 events.
Message Id: 24580
Severity: Error
Log Message: The HP Smart Array SAS/SATA Event Notification Service needs to be
upgraded and cannot process events at this time. The service is being stopped
and processing of HP Smart Array controller events to the Windows system event
log, ProLiant Integrated Management Log (IML) and Integrity System Event Log (SEL)
will not occur until the software is updated.
To upgrade your software, please visit
http://welcome.hp.com/country/us/en/support.html?pageDisplay=drivers
Message Id: 24581
Severity: Informational
Log message: The HP Smart Array SAS/SATA event notification service <status
message>.
<status message> values:

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProLiant Gen9 and is the answer not in the manual?

HP ProLiant Gen9 Specifications

General IconGeneral
Product LineProLiant
GenerationGen9
ChipsetIntel C610 series
Expansion SlotsPCIe 3.0
StorageSATA, SAS, SSD
Network1GbE, 10GbE
ManagementHP iLO (Integrated Lights-Out)
Power SupplyFlexible slot, hot-plug power supplies
Form FactorRack, Tower, Blade
ProcessorIntel Xeon E5-2600 v3/v4 series
RAIDHP Smart Array controllers

Related product manuals