HP Onboard Administrator errors 202
Redundancy: Onboard Administrator redundancy failed to initialize properly. Try
rebooting the Onboard Administrator by reseating the OA module in its bay. If
the problem persists, please call HP support.
Log type: LOG_CRIT, Failure type: SW
Redundancy: Caught Signal SIGSEGV
Redundancy: redund: Failed to startup threads
Log type: LOG_ERR, Failure type: HW
Redundancy: Failed automatic Onboard Administrator failover as a result of
network link loss on the Active OA board
Log type: LOG_ERR, Failure type: SW
Redundancy: Couldn't get random seed
Redundancy: Error communicating via ethernet with the other Onboard Administrator
(heartbeat).
Redundancy: Error communicating via ethernet with the other Onboard Administrator
(timeout).
Redundancy: Error communicating with the other Onboard Administrator.
Redundancy: Failed to get enclosure network
Redundancy: Failed to read OA bay number
Redundancy: Failed to read OA status
Redundancy: Other ([Standby/Active]) OA firmware: v[value:version] - This OA
([Standby/Active]) firmware: v[value:version]
Redundancy: Please upgrade to the latest firmware using [this/the other] Onboard
Administrator which is the active
Redundancy: WARNING: The other OA ([Standby/Active]) is running a different
firmware. OA Redundancy will be degraded
Log type: LOG_NOTICE, Failure type: SW
Redundancy: Assuming active Onboard Administrator network settings.
Redundancy: Enclosure IP mode was [disabled/enabled]
Log type: LOG_INFO, Failure type: SW
Redundancy: Enclosure IP mode configurations have been reset.
Redundancy: Onboard Administrator has now completed the Standby to Active
transition
Redundancy: Onboard Administrator redundancy restored.
Redundancy: Service started ([ACTIVE/STANDBY])
SSO log messages
Log type: LOG_WARNING, Failure type: Info
OA: HP SSO [value] logged into the Onboard Administrator
OA: HP SSO [value] logged into the Onboard Administrator from
[value:remoteAddress]
Log type: LOG_NOTICE, Failure type: Info

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProLiant Gen9 and is the answer not in the manual?

HP ProLiant Gen9 Specifications

General IconGeneral
Product LineProLiant
GenerationGen9
ChipsetIntel C610 series
Expansion SlotsPCIe 3.0
StorageSATA, SAS, SSD
Network1GbE, 10GbE
ManagementHP iLO (Integrated Lights-Out)
Power SupplyFlexible slot, hot-plug power supplies
Form FactorRack, Tower, Blade
ProcessorIntel Xeon E5-2600 v3/v4 series
RAIDHP Smart Array controllers