EasyManuals Logo

HP ProLiant Gen9 User Manual

HP ProLiant Gen9
410 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #281 background imageLoading...
Page #281 background image
Microsoft Windows Event ID and SNMP traps 281
Event identifier: cpqhsmsg.dll - 4626 (Hex)0x84351212 (Service Event)
Log Severity: Warning (2)
Log Message: The Agent failed to process the MOF file to get the data from WMI. Problem with WMI service
or MOF file or wrong file paths used.
Storage agents
Event Identifiers 256-774
Event identifier: cpqstmsg.dll - 256 (Hex)0x84350100 (Service Event)
Log Severity: Warning (2)
Log Message: The Storage Agents service detected an error. The insertion string is: %1. The data contains the
error code.
Event identifier: cpqstmsg.dll - 257 (Hex)0x84350101 (Service Event)
Log Severity: Warning (2)
Log Message: The Storage Agents service could not allocate memory. The data contains the error code.
Event identifier: cpqstmsg.dll - 258 (Hex)0x84350102 (Service Event)
Log Severity: Warning (2)
Log Message: The Storage Agents service could not register with the Service Control Manager. The data
contains the error code.
Event identifier: cpqstmsg.dll - 259 (Hex)0x84350103 (Service Event)
Log Severity: Warning (2)
Log Message: The Storage Agents service could not set the service status with the Service Control Manager.
The data contains the error code.
Event identifier: cpqstmsg.dll - 260 (Hex)0x84350104 (Service Event)
Log Severity: Warning (2)
Log Message: The Storage Agents service could not create an event object. The data contains the error code.
Event identifier: cpqstmsg.dll - 261 (Hex)0x84350105 (Service Event)
Log Severity: Warning (2)
Log Message: The Storage Agents service could not open registry key “%1”. The data contains the error
code.
Event identifier: cpqstmsg.dll - 262 (Hex)0x84350106 (Service Event)
Log Severity: Warning (2)
Log Message: The Storage Agents service could not start any agents successfully.
Event identifier: cpqstmsg.dll - 263 (Hex)0x84350107 (Service Event)
Log Severity: Warning (2)
Log Message: The Storage Agents service could not read the registry value “%1”. The data contains the error
code.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProLiant Gen9 and is the answer not in the manual?

HP ProLiant Gen9 Specifications

General IconGeneral
Product LineProLiant
GenerationGen9
ChipsetIntel C610 series
Expansion SlotsPCIe 3.0
StorageSATA, SAS, SSD
Network1GbE, 10GbE
ManagementHP iLO (Integrated Lights-Out)
Power SupplyFlexible slot, hot-plug power supplies
Form FactorRack, Tower, Blade
ProcessorIntel Xeon E5-2600 v3/v4 series
RAIDHP Smart Array controllers

Related product manuals