HP ProLiant server errors 47
Unsupported DIMM(s) found in system. - DIMM(s) may not be used
Description: Unsupported memory types found in system.
Action: Refer to the applicable server user guide memory requirements and replace with supported DIMMs.
Unsupported PCI Card Detected Remove PCI Card from Slot
Possible cause: The PCI card installed in the slot referenced in the message is strictly not supported on this
system.
Action: Remove the card from the slot reported in the message.
Unsupported power supply detected in bay X
Possible Cause: The power supply in bay X is not supported by the server.
Action: Install a supported power supply in bay X.
For supported power supplies, see the server documentation on the HP website
(http://www.hp.com/support).
Unsupported Processor Detected System will ONLY boot ROMPAQ Utility. System
Halted.
Possible Cause: Processor or processor stepping is not supported by the current system ROM.
Action: See the server documentation for supported processors. If a ROM version exists that supports the
processor, do the following:
1. Power down the server.
2. Insert a Systems ROMPAQ diskette containing the latest ROM version.
3. Boot the system to flash the system to the latest ROM version. Allow 15 minutes for the process to
complete. Successful completion is indicated by a series of beeps of increasing pitch.
USB Tape-based One button Disaster Recovery (OBDR) drive detected.
<<Press F8 for configuration options>>
Select a configuration option:
1. Enable OBDR
2. Exit
Audible Beeps: None
Possible Cause: A USB tape device that supports One Button Disaster Recovery (OBDR) is installed in the
system.
Action:
1. Press 1 or 2.
o Pressing 2 exits the configuration.
o Pressing 1 starts the configuration. The following message appears
Attempting to enable OBDR for the attached USB tape drive...
2. Observe the configuration progress. The following error may appear:
Error - USB tape drive not in Disaster Recovery mode.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProLiant Gen9 and is the answer not in the manual?

HP ProLiant Gen9 Specifications

General IconGeneral
Product LineProLiant
GenerationGen9
ChipsetIntel C610 series
Expansion SlotsPCIe 3.0
StorageSATA, SAS, SSD
Network1GbE, 10GbE
ManagementHP iLO (Integrated Lights-Out)
Power SupplyFlexible slot, hot-plug power supplies
Form FactorRack, Tower, Blade
ProcessorIntel Xeon E5-2600 v3/v4 series
RAIDHP Smart Array controllers

Related product manuals