HP ProLiant server errors 67
Action: Set the Security Override Switch, and then use the iLO RBSU to enable and reset iLO.
1503: iLO 4 ROM-based Setup Utility is disabled.
Possible cause: The RBSU or iLO is disabled and the Security Override Switch is set to OFF.
Action: Enable the ROM-based Setup Utility through RIBCL.
1600 Series
1609 - The server may have a failed system battery. Some...
...configuration settings may have been lost and restored to defaults. Refer to server documentation for more
information. If you have just replaced the system battery, disregard this message.
Audible Beeps: None
Possible Cause: Real-time clock system battery has lost power. The system will lose its configuration every time
AC power is removed (when the system is unplugged from AC power source) and this message displays
again if a battery failure has occurred. However, the system will function and retain configuration settings if
the system is connected to the AC power source.
Action: Replace battery (or add external battery).
1610-Temperature Violation Detected. - Waiting 5 Minutes for System to Cool
...Press Esc key to resume booting without waiting for the system to cool.
WARNING: Pressing Esc is NOT recommended as the system may shutdown unexpectedly.
Audible Beeps: None
Possible Cause: The temperature measured by one of the system temperature sensors has exceeded
acceptable levels. In many cases, this is due to the ambient inlet air temperature exceeding acceptable levels.
Action: Be sure to follow all of the environmental requirements for the server.
• Space and airflow
o Always allow adequate ventilation.
o Always populate the racks with blanking panels and the enclosures with blade blanks.
o Always populate the server with air baffles, blanks, and heatsinks.
o Always operate the server with the access panel installed.
• Temperature
Only operate the server in a room where the temperature does not exceed the recommended
temperature for the server.
For more information about the optimum environment for the server, see the server user guide on the HP
website (http://www.hp.com/support).
1611-CPU Zone Fan Assembly Failure Detected. Either...
...the Assembly is not installed or multiple fans have failed in the CPU zone.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProLiant Gen9 and is the answer not in the manual?

HP ProLiant Gen9 Specifications

General IconGeneral
Product LineProLiant
GenerationGen9
ChipsetIntel C610 series
Expansion SlotsPCIe 3.0
StorageSATA, SAS, SSD
Network1GbE, 10GbE
ManagementHP iLO (Integrated Lights-Out)
Power SupplyFlexible slot, hot-plug power supplies
Form FactorRack, Tower, Blade
ProcessorIntel Xeon E5-2600 v3/v4 series
RAIDHP Smart Array controllers

Related product manuals