HP Smart Array errors 157
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis label> has reported that it previously locked up with code <lockup
code>.
The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.
Message Id 24805
Severity: Warning
Log message: Array controller <controller name / slot information> has reported that
Supercap is enabled but the cache module flash memory is missing. This is an
unsupported configuration.
Message Id 24806
Severity: Warning
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis label> has reported that Supercap is enabled but the cache module
flash memory is missing. This is an unsupported configuration.
The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.
Message Id 24807
Severity: Warning
Log message: Array controller <controller name / slot information> has reported that
the cache module flash memory is installed but Supercap is disabled. This is an
unsupported configuration.
Message Id 24808
Severity: Warning
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis label> has reported that the cache module flash memory is installed
but Supercap is disabled. This is an unsupported configuration.
The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.
Smart Array Windows driver errors
Message Id: 5001
Severity: Error
Log message: The controller in slot %3 (bus %4, device %5, function %6) heartbeat
has not changed in %2 seconds.
Message Id: 5002
Severity: Error
Log message: The driver has taken the failed controller in slot %2 (bus %3, device
%4, function %5) offline.
Message Id: 5003
Severity: Error

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProLiant Gen9 and is the answer not in the manual?

HP ProLiant Gen9 Specifications

General IconGeneral
Product LineProLiant
GenerationGen9
ChipsetIntel C610 series
Expansion SlotsPCIe 3.0
StorageSATA, SAS, SSD
Network1GbE, 10GbE
ManagementHP iLO (Integrated Lights-Out)
Power SupplyFlexible slot, hot-plug power supplies
Form FactorRack, Tower, Blade
ProcessorIntel Xeon E5-2600 v3/v4 series
RAIDHP Smart Array controllers

Related product manuals