HP Smart Array errors 127
<external specification> values:
• “the external controller attached to”
• ""
Message Id: 24673
Severity: Informational
Log message: Power supply number <power supply number> was <inserted / removed>.
This power supply is located in the storage chassis with serial number <serial
number> which is attached to port <port number> of array controller <controller
name / slot information>.
Message Id: 24674
Severity: Warning
Log message: Array controller <controller name / slot information> is reporting
inconsistent data that was previously consistent.<additional data> The
inconsistent data may be caused by a power loss during write activity or by a
drive returning corrupt data. The inconsistent data is between block address
<block address 1> and block address <block address 2> of logical drive <logical
drive number>.
<additional data> values:
• “The party data does not match the data drives.“
• “”
Message identifiers 24675-24699
Message Id: 24675
Severity: Warning
Log message: Data that was previously consistent is now being reported as
inconsistent.<additional data> The inconsistent data may be caused by a power
loss during write activity or by a drive returning corrupt data. The inconsistent
data is between block address <block address 1> and block address <block address
2> of logical drive <logical drive number>. The inconsistent physical drive can
be found in bay <bay number> of box <box number> connected to port <port number>
of array controller <controller name / slot information>.
<additional data> values:
• “The party data does not match the data drives.“
• “”
Message Id: 24676
Severity: Informational
Log message: Surface analysis has repaired an inconsistent stripe on logical drive
<logical drive number>. This repair was conducted by overwriting the
statistically incorrect stripe on the physical drive found in bay <bay number>
of box <box number> connected to port <port number> of array controller
<controller name / slot information>.
Message Id: 24677

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProLiant Gen9 and is the answer not in the manual?

HP ProLiant Gen9 Specifications

General IconGeneral
Product LineProLiant
GenerationGen9
ChipsetIntel C610 series
Expansion SlotsPCIe 3.0
StorageSATA, SAS, SSD
Network1GbE, 10GbE
ManagementHP iLO (Integrated Lights-Out)
Power SupplyFlexible slot, hot-plug power supplies
Form FactorRack, Tower, Blade
ProcessorIntel Xeon E5-2600 v3/v4 series
RAIDHP Smart Array controllers