42 - English
2. SPECIAL MENU FUNCTIONS
To select a new start-up sequence: Place the cursor on
New start-up sequence and press YES. Now press
YES when asked Select new startup?.
Calibrate tilt sensor (5-6-3)
To calibrate, i.e. reset the tilt sensor: Place the
Automower on a horizontal surface. Place the cursor
on Calibrate tilt sensor and press YES. Now press YES
when asked Calibrate tilt sensor?.
STOP button override (5-6-4)
When STOP button override is actuated the
Automower can be started and stopped with the help of
the number 0 instead of the STOP button. This function
is suitable when the display is difficult to read on a
working mower, for example, when charging or running
in Live data mode.
The function is switched off automatically when the
mower is switched off and on using the main switch.
Table 4: Factory settings
Function Value (min – max)
Drive past wire 27cm (15 – 50cm), 11” (6” - 20”)
Reversing distance from charging station 60cm, random ± 20cm (15 – 300cm)
24”, random ± 8” (6” - 120”)
Exit angles 90° – 270° (45° – 315°)
Follow loop out No area activated
Boundary delay 11 minutes
Guide delay 1 7 minutes
Guide delay 2 (only 230 ACX and Solar Hybrid) 7 minutes
Boundary corridor 1 10
Boundary corridor 2 (only 230 ACX and Solar Hybrid) 10
Guide corridor 10
Timer No limitation
Time lock 30 days
Stop protection Deactivated
Settings lock Deactivated
Square mode cutting (EXP-position) 230 ACX: 70 %,
220 AC/Solar Hybrid: 50 % (1 % – 100 %)
Sounds Keypad ON
Sounds Operation OFF
Garden shape Normal