Powermax125 Service Manual 808070 181
9 Power Supply Component Replacement
Set the voltage divider board
The factory presets the voltage divider to 50:1.
1. To change the voltage divider to a different setting:
a. Locate the voltage divider DIP switches on the left side of the power supply. Figure 50 shows the default setting
(50:1) with the number 4 switch up.
Figure 50
b. Set the DIP switches to one of the settings shown in Figure 51.
Figure 51
CAUTION!
The factory-installed internal voltage divider provides a maximum of 16 V under open circuit
conditions. This is an impedance-protected functional extra low voltage (ELV) output to prevent
shock, energy, and fire under normal conditions at the machine interface receptacle and under single
fault conditions with the machine interface wiring. The voltage divider is not fault tolerant and ELV
outputs do not comply with safety extra low voltage (SELV) requirements for direct connection to
computer products.
20:1
21.1:1
30:1
40:1
50:1

Table of Contents

Other manuals for Hypertherm Powermax 125

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm Powermax 125 and is the answer not in the manual?

Hypertherm Powermax 125 Specifications

General IconGeneral
Output Current30-125 A
Input Power15.2 kW
Open Circuit Voltage300 VDC
Gas SupplyClean, dry, oil-free air or nitrogen
Input Power Cable Length10 ft (3 m)
Rated Output Current125 A
Gas TypeAir or nitrogen
Cutting Capacity1-1/4 inch (32 mm)
Pierce Capacity1 inch (25 mm)
Input Voltage200-600 V, 3-PH
Duty Cycle100% @ 125 A
CertificationsCSA
Maximum Clean Cut Thickness1-1/4 inch (32 mm)
Cooling MethodFan-cooled
Torch OptionsHand

Related product manuals