32 Powermax125 Service Manual 808070
2 – Power Supply Setup
Power connection for the Powermax125
Powermax125 3-phase systems are available in the following fixed-voltage configurations:
480 V CSA
600 V CSA
400 V CE
380 V CCC
To maintain CE certification, install power cord kit 228886.
The Hypertherm rated output is 30 – 125 A, 175 VDC.
Table 4 – 480 V CSA
Table5 – 600V CSA
Table6 – 400V CE
Input voltage (V) 480
Input current (A) at rated output (21.9 kW) 31
Input current (A) at arc stretch 50
Fuse, slow-blow (A) 50
Voltage tolerance +20% / -15%
Input voltage (V) 600
Input current (A) at rated output (21.9 kW) 24
Input current (A) at arc stretch 38
Fuse, slow-blow (A) 40
Voltage tolerance +10% / -15%
Input voltage (V) 400
Input current (A) at rated output (21.9 kW) 36
Input current (A) at arc stretch 55
Fuse, slow-blow (A) 60
Voltage tolerance +20% / -15%