Four: Programming the PE953 Hand-Held Controller 45
Providing a brighter solution.™
Press and release the3. <2> function button to select CALIBRATE
TEMPS. The screen refreshes, as shown.
Using POOL as an example, press the4. <1> function button to
calibrate the POOL temperature setting. The screen displays only
the POOL setting, as shown.
The AIR temperature calibration is done the same way by
pressing the <2> function button for AIR and continuing below.
Press the 5. UP or DOWN arrow button to add or subtract degrees
from the temp that will be displayed for POOL (or SPA) temperature on the Hand-Held
screen.
NOTE: You can set the temperature offset by ±20˚F.
Press the 6. <ENTER> button to save your changes. The screen adds the word SUCCESSFUL,
then returns to Step 5.
Press the 7. <ENTER> button again as necessary to return to the Main screen.
Configuring for a Booster (Cleaner) Pump
If the pool/spa installation includes a booster (cleaner) pump, you need to program the Hand-
Held Controller to identify the pump and/or pump speed that must be active for the pump to
operate.
If necessary, press and release any button on the Hand-Held 1.
Controller to wake it from sleep. If the screen is not displaying
LEARN MODE, press and hold the <P/S> and <ENTER> buttons at
the same time to put the device into programming mode. You are in
programming mode when the LEARN MODE screen is displayed, as
shown at the right.
Press the 2. DOWN arrow button until you see the PE653 OPTION
screen, as shown.
Press and release the3. <3> function button to select CLEANER. The
screen refreshes, as shown.
Press the 4. UP or DOWN arrow button to change from OFF to CIR1
(circuit or button 1), then press the <ENTER> button. The screen
adds the word SUCCESSFUL, then returns to the programming
screen.
NOTE: If a variable speed pump has been installed, you may select one of the four variable
speed pump speeds for this function.
Press the 5. <ENTER> button again to return to the Main screen.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Intermatic PE653RC Multi Wave and is the answer not in the manual?

Intermatic PE653RC Multi Wave Specifications

General IconGeneral
BrandIntermatic
ModelPE653RC Multi Wave
CategoryControl Systems
LanguageEnglish

Related product manuals